LTZ Series- with Heating Function
APLICACIONES
LTZ variable frequency belt heating function series, temperature control range: -40℃~+90℃, temperature control accuracy: ±0.3℃. The variable frequency unit adopts advanced variable frequency technology to accurately control the compression and fan operating speed, and quickly cools through intelligent adjustment of the electronic expansion valve.
Características del producto
Parámetros del producto
High efficiency and energy saving: The variable frequency compressor unit changes the operating speed of the DC compressor at any time according to the user's cold and hot load requirements through the built-in variable frequency device, thereby avoiding the compressor and the full load of the electric heating to compete, maintain the stable working state of the unit, and achieve energy saving.
Rapid cooling: The variable frequency unit adopts advanced variable frequency technology to accurately control the compression and fan operating speed, and quickly cools through intelligent adjustment of the electronic expansion valve.
Ultra-low noise: The variable frequency unit adopts a variable frequency scroll or twin-rotor compressor, which greatly reduces the gyroscopic imbalance, making the vibration of the unit very small, about 1/2 of that of a conventional compressor, combined with multiple noise reduction measures, extremely quiet.
High environmental adaptability: The variable frequency unit adopts low frequency starting, small starting current, and small impact on the power grid. It has strong adaptability to voltage and can be started under a wide voltage range.
Long life: The variable frequency unit will not start and stop frequently, effectively reducing the loss of the unit when starting and stopping, and extending the life of the unit.
Modelo | LTZ4-2H LTZ4-2WH |
LTZ4-4H LTZ4-4WH |
LTZ4-6H LTZ4-6WH |
LTZ4-10H LTZ4-10WH |
|
Rango de temperatura |
-40℃~90℃ |
||||
Precisión del control de temperatura | PLC controller, control the water tank outlet temperature screen | ||||
Precisión del control de temperatura | ±0.3℃ | ||||
Información sobre la temperatura | Retroalimentación de temperatura PT100 (temperatura de entrada, temperatura de salida) | ||||
Potencia calorífica | 2,5 kW | 5,5 kW | 7,5 kW | 10kW | |
Capacidad de refrigeración | -15℃ | 2kW | 4,5 kW | 7kW | 11,5 kW |
-35℃ | 0.7kW | 1,5 kW | 2.3kW | 3,8 kW | |
Bomba de circulación MAX | 20L/min 2bar | 35L/min 2bar | 50L/min 2bar | 100L/min 2bar | |
Compresor | Famous brand compressor | ||||
Evaporador | Intercambiador de calor de placas | ||||
Panel de control | 7-inch color touch screen displays set temp and measured temp, records temp curve, and exports data in Excel format | ||||
Protección de seguridad | Self-diagnosis function; refrigerator overload protection; high and low pressure sensors, overload relays, thermal protection devices and other safety protection functions. | ||||
Refrigerante | R-404A/R507C | ||||
Tamaño de la interfaz | ZG3/4 | ZG3/4 | ZG1 | ZG1 | |
Potencia | AC380V 50HZ/ AC460V 50HZ | ||||
Material de la carcasa | Cold rolled sheet (REL7035) | ||||
Protocolo de comunicación | Communication protocol MODBUS RTU protocol RS485 interface |
Modelo | LTZ-2H LTZ-2WH |
LTZ-4H LTZ-4WH |
LTZ-6H LTZ-6WH |
LTZ-10H LTZ-10WH |
|
Rango de temperatura |
5℃~90℃ (Ethylene glycol water solution) |
||||
Precisión del control de temperatura | PLC controller, control the water tank outlet temperature screen | ||||
Precisión del control de temperatura | ±0.3℃ | ||||
Información sobre la temperatura | PLC controller, control the water tank outlet temperatureh screen Temperature feedback PT100 (inlet temperature, outlet temperature) | ||||
Potencia calorífica | 3,5 kW | 5,5 kW | 7,5 kW | 15 kW | |
Capacidad de refrigeración | 10℃ | 4kW | 8 kW | 12kW | 20 kW |
Bomba de circulación MAX | 20L/min 2bar | 35L/min 2bar | 50L/min 2bar | 100L/min 2bar | |
Compresor | Famous brand compressor | ||||
Evaporador | Intercambiador de calor de placas | ||||
Panel de control | 7-inch color touch screen displays set temp and measured temp, records temp curve, and exports data in Excel format | ||||
Protección de seguridad | Self-diagnosis function; refrigerator overload protection; high and low pressure sensors, overload relays, thermal protection devices and other safety protection functions. | ||||
Refrigerante | R-134A / R407C | ||||
Tamaño de la interfaz | ZG3/4 | ZG3/4 | ZG1 | ZG1 | |
Potencia | AC380V 50HZ/ AC460V 50HZ | ||||
Material de la carcasa | Cold rolled sheet (REL7035) | ||||
Protocolo de comunicación | Communication protocol MODBUS RTU protocol RS485 interface |