Enfriadores de tornillo industriales serie LG
APLICACIONES
Applicable to various chemical, pharmaceutical, mechanical and other fields as process cooling sources, can provide -110℃~30℃ refrigeration medium, can be used as ice storage, low temperature air supply and other process cooling sources required by production processes.
Características del producto
Parámetros del producto
This series of screw chillers has a total of 6 temperature sections to choose from, all of which are water-cooled.
Modelo | LG1-75W | LG1-100W | LG1-140W | LG1-180W | LG1-230W | LG1-280W | |
Temperatura | 5℃~30℃ | ||||||
Capacidad de refrigeración 7℃ |
kW | 236 | 328 | 468 | 608 | 762 | 936 |
Kcal/hr*10³ | 202.9 | 282.1 | 402.5 | 522.9 | 655.3 | 805.0 | |
Potencia | 3N/400V/50HZ | ||||||
Cooling input power at (7℃) | 64 | 84 | 120 | 155 | 191 | 236 | |
Compresor | Formulario | semi-closed double screw compressor | |||||
Heat control range | 25%~100% | ||||||
Chilled water | Formulario | Plate, dry, overflow or falling film heat exchanger | |||||
Chilled water volumeT/H | 40 | 56 | 80 | 104 | 131 | 160 | |
Water pressure drop | 40~80 | ||||||
Tamaño de la conexión | DN80 | DN100 | DN125 | DN150 | |||
Agua de refrigeración | Formulario | Horizontal tubular heat exchanger | |||||
Cooling water volumeT/H | 51 | 71 | 101 | 131 | 163 | 201 | |
Water pressure drop | 40~80 | ||||||
Tamaño de la conexión | DN80 | DN100 | DN150 | DN200 | |||
Security device | High and low voltage protection, anti-icing, heat release protection (double), safety valve, overload protection, under-phase, reverse phase, under voltage, over voltage, water flow protection, etc |
||||||
RefrigerantR404A | Charge Kg | 49 | 56 | 69 | 115 | 133 | 180 |
Dimensión | Length cm | 313 | 314 | 314 | 328 | 330 | 340 |
Width cm | 110 | 110 | 110 | 110 | 110 | 110 | |
Height cm | 157 | 178 | 180 | 202 | 207 | 220 | |
Unit weight | 1740 | 2480 | 2870 | 3400 | 3600 | 4050 | |
Working weight | 1890 | 2580 | 3120 | 3700 | 3900 | 4350 |
Security device:High and low voltage protection, anti-icing, heat release protection (double), safety valve, overload
protection, under-phase, reverse phase, under voltage, over voltage, water flow protection, etc
Modelo | LG2-75W | LG2-100W | LG2-140W | LG2-180W | LG2-230W | LG2-280W | |
Temperatura | -25℃~5℃ | ||||||
Capacidad de refrigeración -20℃ |
kW | 80 | 111 | 158 | 206 | 259 | 318 |
Kcal/hr*10³ | 68.8 | 95.5 | 135.9 | 177.2 | 222.7 | 273.5 | |
Potencia | 3N/400V/50HZ | ||||||
Cooling input power at (-20℃) | 56 | 74 | 105 | 136 | 166 | 205 | |
Compresor | Formulario | semi-closed double screw compressor | |||||
Heat control range | 25%~100% | ||||||
Chilled water | Formulario | Plate, dry, overflow or falling film heat exchanger | |||||
Chilled water volumeT/H | 24 | 32 | 46 | 59 | 75 | 92 | |
Water pressure drop | 40~80 | ||||||
Tamaño de la conexión | DN65 | DN80 | DN100 | DN125 | |||
Agua de refrigeración | Formulario | Horizontal tubular heat exchanger | |||||
Cooling water volumeT/H | 26 | 35 | 50 | 65 | 80 | 99 | |
Water pressure drop | 40~80 | ||||||
Tamaño de la conexión | DN80 | DN100 | DN125 | DN150 | |||
Security device | High and low voltage protection, anti-icing, heat release protection (double), safety valve, overload protection, under-phase, reverse phase, under voltage, over voltage, water flow protection, etc |
||||||
RefrigerantR404A | Charge Kg | 60 | 81 | 113 | 146 | 184 | 222 |
Dimensión | Length cm | 300 | 310 | 320 | 330 | 340 | 350 |
Width cm | 160 | 160 | 170 | 180 | 180 | 180 | |
Height cm | 225 | 225 | 235 | 235 | 245 | 245 | |
Unit weight | 2400 | 2600 | 2700 | 2800 | 3000 | 3100 | |
Working weight | 2550 | 2750 | 2850 | 2950 | 3150 | 3250 |
Modelo | LG4-75W | LG4-100W | LG4-140W | LG4-180W | LG4-230W | LG4-280W | |
Temperatura | -45℃~-10℃ | ||||||
Capacidad de refrigeración -40℃ |
kW | 50 | 70 | 95 | 120 | 155 | 180 |
Kcal/hr*10³ | 43 | 60.2 | 81.7 | 103.2 | 133.3 | 154.8 | |
Potencia | 3N/400V/50HZ | ||||||
Cooling input power at (-40℃) | 35 | 48 | 65 | 82 | 106 | 113 | |
Compresor | Formulario | semi-closed double screw compressor | |||||
Heat control range | 25%~100% | ||||||
Chilled water | Formulario | Plate, dry, overflow or falling film heat exchanger | |||||
Chilled water volumeT/H | 23 | 32 | 44 | 56 | 72 | 83 | |
Water pressure drop | 40~80 | ||||||
Tamaño de la conexión | DN65 | DN80 | DN100 | DN125 | |||
Agua de refrigeración | Formulario | Horizontal tubular heat exchanger | |||||
Cooling water volumeT/H | 16 | 20 | 30 | 36 | 46 | 60 | |
Water pressure drop | 40~80 | ||||||
Tamaño de la conexión | DN65 | DN80 | DN100 | DN125 | |||
Security device | High and low voltage protection, anti-icing, heat release protection (double), safety valve, overload protection, under-phase, reverse phase, under voltage, over voltage, water flow protection, etc |
||||||
RefrigerantR404A | Charge Kg | 65 | 87 | 122 | 158 | 199 | 240 |
Dimensión | Length cm | 380 | 420 | 430 | 480 | 500 | 520 |
Width cm | 160 | 180 | 220 | 230 | 340 | 450 | |
Height cm | 225 | 225 | 235 | 235 | 245 | 245 | |
Unit weight | 4200 | 4300 | 4400 | 4500 | 4600 | 4700 | |
Working weight | 4350 | 4450 | 4550 | 4650 | 4750 | 4850 |
Modelo | LG6-75 | LG6-100W | LG6-140W | LG6-180W | LG6-230W | LG6-280W | |
Temperatura | -60℃~-10℃ | ||||||
Capacidad de refrigeración -55℃ |
kW | 66 | 87 | 121 | 158 | 202 | 238 |
Kcal/hr*10³ | 56.7 | 74.8 | 104.0 | 135.8 | 173.7 | 204.6 | |
Potencia | 3N/400V/50HZ | ||||||
Cooling input power at (-55℃) | 103 | 135 | 192 | 249 | 310 | 375 | |
Compresor | Formulario | semi-closed double screw compressor | |||||
Heat control range | 25%~100% | ||||||
Chilled water | Formulario | Plate, dry, overflow or falling film heat exchanger | |||||
Chilled water volumeT/H | 34 | 45 | 63 | 82 | 105 | 123 | |
Water pressure drop | 40~80 | ||||||
Tamaño de la conexión | DN80 | DN100 | DN125 | ||||
Agua de refrigeración | Formulario | Horizontal tubular heat exchanger | |||||
Cooling water volumeT/H | 26 | 34 | 48 | 62 | 79 | 94 | |
Water pressure drop | 40~80 | ||||||
Tamaño de la conexión | DN80 | DN100 | DN125 | DN150 | |||
Security device | High and low voltage protection, anti-icing, heat release protection (double), safety valve, overload protection, under-phase, reverse phase, under voltage, over voltage, water flow protection, etc |
||||||
RefrigerantR404A/R23 | Charge Kg | 29/22 | 38/29 | 53/41 | 69/54 | 89/69 | 105/82 |
Dimensión | Length cm | 420 | 420 | 450 | 450 | 450 | 450 |
Width cm | 200 | 210 | 220 | 225 | 230 | 235 | |
Height cm | 237 | 240 | 245 | 250 | 255 | 255 | |
Unit weight | 4800 | 4900 | 5000 | 5100 | 5200 | 5300 | |
Working weight | 4950 | 5050 | 5150 | 5250 | 5350 | 5450 |
Modelo | LG8-75W | LG8-100W | LG8-140W | LG8-180W | LG8-230W | LG8-280W | |
Temperatura | -80℃~-30℃ | ||||||
Capacidad de refrigeración -75℃ |
kW | 36 | 48 | 67 | 88 | 112 | 131 |
Kcal/hr*10³ | 30.9 | 41.3 | 54.2 | 72.2 | 96.3 | 112..3 | |
Potencia | 3N/400V/50HZ | ||||||
Cooling input power at (-75℃) | 83 | 110 | 156 | 203 | 254 | 308 | |
Compresor | Formulario | semi-closed double screw compressor | |||||
Heat control range | 25%~100% | ||||||
Chilled water | Formulario | Plate, dry, overflow or falling film heat exchanger | |||||
Chilled water volumeT/H | 22 | 30 | 36 | 55 | 70 | 82 | |
Water pressure drop | 40~80 | ||||||
Tamaño de la conexión | DN65 | DN80 | DN100 | ||||
Agua de refrigeración | Formulario | Horizontal tubular heat exchanger | |||||
Cooling water volumeT/H | 18 | 23 | 31 | 43 | 54 | 65 | |
Water pressure drop | 40~80 | ||||||
Tamaño de la conexión | DN65 | DN80 | DN100 | DN125 | |||
Security device | High and low voltage protection, anti-icing, heat release protection (double), safety valve, overload protection, under-phase, reverse phase, under voltage, over voltage, water flow protection, etc |
||||||
RefrigerantR404A/R508B | Charge Kg | 26/20 | 34/26 | 48/35 | 61/47 | 80/62 | 94/74 |
Dimensión | Length cm | 420 | 420 | 450 | 450 | 450 | 450 |
Width cm | 200 | 210 | 220 | 225 | 230 | 235 | |
Height cm | 237 | 240 | 245 | 250 | 255 | 255 | |
Unit weight | 4800 | 4900 | 5000 | 5100 | 5200 | 5300 | |
Working weight | 4950 | 5050 | 5150 | 5250 | 5350 | 5450 |
Modelo | LG11-75W | LG11-100W | LG11-140W | LG11-180W | LG11-230W | LG11-280W | |
Temperatura | -110°C~ -50°C | ||||||
Capacidad de refrigeración -105℃ |
kW | 9 | 12 | 16 | 22 | 28 | 32 |
Kcal/hr*10³ | 7.7 | 10.3 | 13.8 | 18.9 | 24.1 | 27.5 | |
Potencia | 3N/400V/50HZ | ||||||
Cooling input power at (-105℃) | 56 | 75 | 105 | 135 | 172 | 210 | |
Compresor | Formulario | semi-closed double screw compressor | |||||
Heat control range | 25%~100% | ||||||
Chilled water | Formulario | Plate, dry, overflow or falling film heat exchanger | |||||
Chilled water volumeT/H | 3 | 4 | 5 | 7 | 8 | 10 | |
Water pressure drop | 40~80 | ||||||
Tamaño de la conexión | DN40 | DN50 | DN65 | ||||
Agua de refrigeración | Formulario | Horizontal tubular heat exchanger | |||||
Cooling water volumeT/H | 8 | 10 | 14 | 19 | 24 | 27 | |
Water pressure drop | 40~80 | ||||||
Tamaño de la conexión | DN50 | DN65 | DN80 | ||||
Security device | High and low voltage protection, anti-icing, heat release protection (double), safety valve, overload protection, under-phase, reverse phase, under voltage, over voltage, water flow protection, etc |
||||||
Refrigerante | R14/R23/R404A | ||||||
Dimensión | Length cm | 250 | 300 | 350 | 400 | 450 | 500 |
Width cm | 145 | 160 | 160 | 160 | 200 | 220 | |
Height cm | 225 | 225 | 245 | 245 | 260 | 265 | |
Unit weight | 2200 | 3000 | 3500 | 4000 | 4500 | 5000 | |
Working weight | 2350 | 3150 | 3650 | 4150 | 4650 | 5150 |
Get in touch with our reactor chiller experts
Can't find a suitable chiller? Or don't know how to choose a chiller? Contact us now to get chiller details and prices
Contacto
Envíenos su solicitud y nos pondremos en contacto con usted en 24 horas
La serie de frecuencia variable ahorra un 20% más de energía que la serie de frecuencia fija
Minimum order quantity: 1, 1 unit is also wholesale price.

Your quality chiller manufacturer
lneya uses reliable international brand material accessories, Siemens controllers, Taikang compressors, etc. You can expect our chillers to provide precise temperature control and the best results.
¿Por qué elegir lneya como proveedor de control de temperatura?
Años de experiencia
Clientes satisfechos
m² Área de producción
Tecnologías patentadas
Visite la fábrica de LNEYA
Recomendar productos