The WTD vacuum chiller has a temperature control accuracy of up to ±0.3℃ and a temperature range of -70℃ to 300℃, giving you a more accurate, stable and efficient temperature control experience.
más bajo
Más alto
Precisión del control de temperatura
Medio y material
Póngase en contacto con el ingeniero de ventas de LNEYA
para catálogo o precio.
Modelo | WTD-120M | WTD-255 | WTD-455 | WTD-755 | WTD-275V | |
Rango de temperatura | -5°C~120°C | -25°C~200°C | -45°C~250°C | -70°C~200°C | -20°C~300°C | |
Temp resolution | 0.1K | |||||
Control model | PID Adaptive controller | |||||
Potencia calorífica | 2kW | 5,5 kW | 5,5 kW | 5,5 kW | 7,5 kW | |
Cooling capacity kW | 300°C | 7,5 kW | ||||
200°C | 5,5 kW | 5,5 kW | 5,5 kW | 7,5 kW | ||
100°C | 1,5 kW | 5,5 kW | 5 kW | 5 kW | 7,5 kW | |
20°C | 1 kW | 5,5 kW | 5 kW | 5 kW | 5,5 kW | |
-15°C | 2,5 kW | 4 kW | 4 kW | 2,5 kW | ||
-35°C | 1,5 kW | 3 kW | ||||
-60°C | 1.1kW | |||||
Bomba de circulación máx. | 7L/min 2,5bar | 25L/min 3bar | 25L/min 3bar | 25L/min 3bar | 25L/min 3bar | |
Temp sensor | PT100 | PT100 | PT100 | PT100 | PT100 | |
Cooling way | Refrigerado por aire | Air cooled+water cooled | ||||
Heating-conduction medium | Synthetic heat conducting oil | |||||
Potencia 380V 50HZ | 220V 3.1kW | 9.5kW MAX | 10kW MAX | 12kW MAX | 15kW MAX |
Floor space
The WTD recirculating chiller heater uses a plate heat exchanger with a compact structure and a small footprint, which is suitable for use in places with limited space. The bottom is equipped with 4 casters, which is convenient for you to move the position at any time according to your needs.
Core accessories
The accessories of the WTD industrial chiller heater are basically internationally renowned brands. For example, the compressor uses Secop, Emerson Copeland and French Tecumseh, etc.; the dry filter uses Danfoss; the contactor/circuit breaker uses Schneider.
Cannabis extraction
Cannabinoids and other active ingredients contained in cannabis are important for medical treatment, but a key factor in cannabis extraction is temperature control in processes such as extraction, distillation, crystallization, and solvent recovery. Only by accurately and stably controlling the temperature environment with the help of chiller heater units can we help improve the efficiency of extraction and the quality of products.
productos farmacéuticos
In the pharmaceutical process, researchers need to use laboratory thermostats to change the temperature environment, understand the stability of drugs at different temperatures, and observe the changes in their efficacy and activity.