Puntos de atención para la inspección diaria de equipos de control de baja temperatura a menos 30℃
The low temperature control equipment at minus 30 degrees Celsius is a refrigeration unit or also called a refrigeration unit. The difference from the chiller is the temperature range. It is a commonly used low-temperature equipment in the industry and needs to operate for a long time. So what points should be paid attention to in daily inspection during operation?

1. Power supply part inspection
Before installation, the low temperature control equipment of minus 30 degrees Celsius will make a plan for the surrounding installation environment, circuit and power supply. If the conditions and standards are suitable, the installation will be carried out, and the installation will be re-planned if the conditions are not suitable. After a long period of use, check the power supply part to see if the power supply accessories are damaged, whether the wires inside and outside the equipment are aging, and whether there is damage. If there are problems, check and correct them in time.
2. Refrigerant inspection
The refrigeration effect in the low temperature control equipment of minus 30 degrees Celsius is a more critical part. If the refrigerant leaks, it will affect the refrigeration temperature, fail to achieve the expected refrigeration effect, and affect the overall work progress. While checking the refrigerant of the low temperature control equipment at minus 30 degrees Celsius, check whether the joints of the relevant parts are loose or cracked. If there is a problem, solve it quickly to avoid refrigerant leakage. If a refrigerant leak is found, it needs to be supplemented, and it needs to be added in accordance with relevant standards.
3. Pipeline inspection
The low temperature control equipment of minus 30 degrees Celsius needs to be inspected after a certain period of time to see if there is any leakage. If a leak is found, it needs to be repaired, and then used after checking that there is no leakage.
Recomendaciones relacionadas
-
La existencia de la destilación y el control de temp. durante la destilación-SUNDI control dinámico de temp.
979Distillation exists in industries such as biopharmaceutical and petrochemical industries. Laboratory distillation includes vacuum distillation, short-path distillation, thin-film distillation, steam distillation, batch distillation, azeotropic dis...
Ver detalles -
How to Choose Water Chiller Units in Small Factories
1128Professional water chiller factory said that the quality of equipment can be seen from the three main components of small water chiller units. The most important one is the compressor, which is the heart of the unit and the most critical component...
Ver detalles -
Wafer thin film deposition temperature control equipment chiller usage environment
998Usage environment for wafer thin film deposition cooling chiller
Ver detalles -
We are LNEYA-a manufacturer of chillers
939There are many manufacturers of industrialchillers in the world, especially JULABO, huber, etc. that are known in theindustry. How much do you know about the production technology of industrialchillers? Now, in many industrial productions, indu...
Ver detalles