Descripción de la presión del refrigerador específico de laboratorio
En laboratory-specific chiller is one of the more popular equipments in the mechanical equipment industry. For this reason, the relevant pressure instructions have been specially compiled to help you better understand the laboratory-specific chiller.
The reference value of the test chamber-specific chiller and the pressure resistance of the piping system components refers to the design given pressure related to the mechanical strength of the pipeline components. The nominal pressure is generally expressed by PN. Nominal pressure—the compressive strength of the product at the reference temperature, expressed in PN, unit: MPa, reference temperature: different materials, the reference temperature is also different, for example, the steel reference temperature is 250 ° C, the nominal pressure is 1.0 Mpa, Recorded as: PN 1.0 Mpa.
The working pressure of the special chiller in the laboratory refers to the large pressure specified by the high working temperature of the pipeline conveying medium for the operation safety of the pipeline system. The working pressure is generally expressed by Pt.

The design chiller design pressure of the laboratory refers to the large instantaneous pressure of the water supply pipe system acting on the inner wall of the pipe. The sum of the working pressure and the residual water hammer pressure is generally used. The design pressure is generally expressed by Pe. The test pressure refers to the pressure to be achieved by the pipeline, container or equipment under the pressure resistance and air tightness test. The test pressure is generally expressed by Ps.
The nominal chiller pressure of the laboratory is a nominal pressure artificially specified for the convenience of design, manufacture and use. The unit of this nominal pressure is actually the pressure, and the pressure is the common name of Chinese. The unit is “Pa”. Not “N”. The nominal pressure of a pressure vessel refers to the nominal pressure of the pressure vessel flange. The nominal pressure of the pressure vessel flange is generally divided into seven grades, namely 0.25, 0.60, 1.00, 1.60, 2.50, 4.00, 6.40 MPa.
In general, the pressure can be divided into: test pressure > nominal pressure > design pressure > working pressure, so, everyone understands?
Recomendaciones relacionadas
-
Refrigeration Principle Of Low Temperature Chiller
952The refrigeration principle of the so-called low temperature chiller is to use the artificial method, compressor refrigeration, through energy consumption, in a cycle process, in the process that cooling materials take away the heat. Generally spe...
Ver detalles -
How is the refrigerant installed in the vocs condensing unit?
1235The vocs condensing equipment is LNEYA's equipment for condensing adsorption of various vocs gases. Among them, the refrigerant of vocs condensing equipment is also indispensable. So, how should the refrigerant be treated? For various refrigeratio...
Ver detalles -
How to Maintain Low Temp Chillers
989Low temp chiller is a kind of refrigeration mechanical equipment which needs to be used in many industrial production operations. It can provide very good refrigeration technology for different production operations and ensure the smooth progress ...
Ver detalles -
Desventajas y ventajas del sistema general de circulación de la calefacción por aceite térmico
1064El sistema de circulación de calefacción de aceite por conducción de calor adopta una estructura de bucle totalmente cerrado para actuar directamente sobre la energía calorífica hacia el medio calentado. Sus ventajas son: (1) Debido a la renovación continua de la superficie de transferencia de calor, la pérdida de calor es s...
Ver detalles