Relación Entre La Temperatura De Condensación Y La Temperatura De Condensación En Ultrabaja Temperatura
The chilling temperature of the enfriadores de recirculación a temperatura ultrabaja refers to the temperature at which the state of the substance changes from a gaseous state to a liquid state under a certain pressure. Different substances have different condensation temperatures. For the same substance, changes in external pressure can also cause changes in the condensing temperature. The condensation temperature of the pure substance is a temperature point, and for the mixture, the boiling range elongation condensation is a temperature range. In general, as the outside air pressure increases, the condensing temperature also rises, and vice versa. In short, it is a function of matter, composition and pressure.
The level of condensation temperature depends mainly on the temperature and flow rate of the cooling medium, the condensation area and the form of the condenser. Reducing the condensing temperature can increase the refrigeration capacity of the compressor and reduce the power consumption, thereby increasing the refrigeration coefficient and improving the economics of operation. However, the condensing temperature should not be too low, otherwise it will affect the circulation of the refrigerant, and the cooling capacity will decrease. If the condensing temperature is too high, not only the cooling capacity will decrease, but also the power consumption will increase, and the exhaust temperature of the compressor will increase, the temperature of the lubricating oil will increase, and the viscosity will decrease.
There is also a certain correspondence between the condensation temperature of the ultra low temperature recirculating chiller and the condensing pressure. Therefore, the adjustment of the condensing temperature can also be achieved by adjusting the condensing pressure. When the temperature of the cooling medium (water or air) is constant, the adjustment of the condensing pressure can be achieved by changing the flow rate and the condensation area of the cooling medium. The flow rate of the cooling medium is increased, and the flow rate is correspondingly increased, the heat transfer temperature difference can be reduced, thereby reducing the condensation temperature; and increasing the heat transfer area can also achieve the purpose of reducing the condensation pressure.
Recomendaciones relacionadas
-
Is the centrifugal pump or the volumetric pump selected in the pharmaceutical laboratory?
954In the pharmaceutical laboratory, a variety of refrigeration equipment is used more, then as a more common equipment - pumps, mainly centrifugal pumps, volumetric pumps. Then, the user friend should have a better understanding of their performance...
Ver detalles -
Cuál es el refrigerante de la enfriadora de recirculación
1042Diferentes industrias tienen diferentes requisitos para la temperatura de refrigeración del enfriador de recirculación, por lo que el refrigerante seleccionado también es diferente. A la hora de elegir un enfriador de recirculación, también es necesario...
Ver detalles -
Ethylene glycol refrigeration unit made a strong attack and created LNEYA brand in 12 years
1309Performance enhanced positioning When performing the cooling and heating reaction, in many cases, the refrigerant cannot cool the object to be cooled by itself. Therefore, we need a coolant (or refrigerant) to cool the refrigeration system in a re...
Ver detalles -
Instructions for use of various components of high and low temperature cycle machine
1141In the high and low temperature cycle machine, each accessory has its own performance advantages. When running, we need to have a clear understanding of each accessory in order to run the device better. The compressor functions to compress and dri...
Ver detalles