Closed cycle heating system temperature deviation description
If the temperature deviation occurs in the closed cycle heating system during use, it is necessary to check to see if there is any problem in each link, and solve the problem in time.
In the steady state, the closed loop heating system displays the difference between the average value of the temperature and the average measured temperature at the center point of the workspace. (Note: The average display temperature here refers to the average display temperature of the temperature control instrument of the device). In the closed state of the closed circulation heating system (chamber), the measurement points of the working space are measured for the upper and lower deviations of the high temperature and the MIN temperature from the nominal temperature within a prescribed time. The object of the closed cycle heating system is that the temperature control instrument of the device displays the average temperature and evaluates the deviation from the reference point. Obviously, this has nothing to do with temperature uniformity. The closed-loop heating system temperature deviation index is easy to implement because it only evaluates the temperature average of the equipment temperature control meter.
LNEYA closed-loop heating system is dynamic constant temperature control of cold and heat source in high pressure reactor, dynamic constant temperature control of double-layer glass reactor cold and heat source, dynamic constant temperature control of double-layer reactor cold and heat source, and constant temperature of microchannel reactor Control; small thermostatic control system, temperature control of steaming system, low temperature and high temperature aging test of materials, combined chemical source cold source heat source constant temperature control, semiconductor equipment cooling and heating, vacuum chamber cooling and heating constant temperature control. The closed-loop heating system adopts a fully closed pipeline design and uses a high-efficiency plate heat exchanger to reduce the demand for thermal fluid while improving the heat utilization rate of the system and achieving rapid rise and fall temperatures. The heat-conducting medium is in a closed system with an expansion vessel. The heat-conducting medium in the expansion vessel does not participate in the circulation. Whether it is high temperature or low temperature, the temperature of the expansion tank is normal temperature to 60 degrees, which can reduce the absorption and evaporation of the heat-conducting medium during operation. risk.
The temperature deviation of the closed loop heating system is related to its temperature accuracy. The temperature accuracy of different closed loop heating systems is related to the performance of the system. Therefore, users should know how to understand the closed loop heating system at the beginning. Temperature control accuracy. (This article is from the source network, if there is any infringement, please contact LNEYA to delete, thank you.)
Recomendaciones relacionadas
-
Process description of LNEYA screw chiller
1033LNEYA screw chiller is suitable for all kinds of chemical, pharmaceutical, mechanical and other fields of production process cold source, can provide -25 ° C ~ 30 ° C chilled water, can be used as ice cold storage, low temperature air supply and o...
Ver detalles -
Why is the mode of cooling water circulator mainly water circulation?
900Cooling water circulator is a way to use water for cooling. With the increase in ambient temperature, many companies have also found that the use of circulating water is increasing. The supplement of circulating water is aimed at the water cooling...
Ver detalles -
Characteristics of the evaporator of LNEYA screw chiller
1612The amount of cooling capacity of the screw chiller is directly related to the energy consumption and operational economics of the entire unit, which is worthy of attention. Especially when designing a cold station, there is no single chiller in t...
Ver detalles -
Low temperature chilled lubricant selection considerations
1237When you use a cryogenic chilled, you definitely want to know about all aspects of the cryocooler. But one of the things that needs everyone's attention is that the type of lubricant for the chilled is chosen because there are many influencing fac...
Ver detalles