¿Qué pasará con el sobreenfriamiento del refrigerador de baja temperatura?
As we all know, the refrigerador de baja temperatura is a kind of professional refrigeration design widely used in industry. Although it can provide an effective cryogenic environment, there are some abnormal phenomena in over-refrigeration. Usually, the lowest temperature of the refrigerador de baja temperatura can only reach – 40 degrees. The main reason is limited by the limit operating conditions of single-stage piston compressor. If the evaporator temperature of the chiller is too low, the following problems will arise when it exceeds the limit operating conditions.
If the refrigerador de baja temperatura is excessively refrigerated, it will have a great impact on the use function of the refrigerador de baja temperatura product itself. The actual compression process deviates from the equal compression process to a great extent. The compressor gas transmission coefficient of the chiller decreases, and the compressor gas transmission capacity will be greatly reduced. This is very disadvantageous to the service life of the refrigerador de baja temperatura products.
If the refrigerador de baja temperatura is over-refrigerated for a long time, the influence on the compressor inside the refrigerador de baja temperatura can not be ignored. When the compressor is over refrigerated, the exhaust temperature of the compressor is too high, and the lubricating oil on the cylinder surface of the compressor becomes thinner, which makes the lubricating condition worse. It may even cause the carbonization of lubricating oil, the phenomenon of cylinder pulling and the improper sealing of valve plates.
Recomendaciones relacionadas
-
2019 CPHl China | LNEYA W5P22 Exhibition Site&Wonderful
1033From June 18th to June 20th, 2019, the 19th World Pharmaceutical Raw Materials China Exhibition - CPhI China 2019 was held at the Shanghai New International Expo Center. LNEYA took a variety of equipment to the W5P22 booth, which lasted for three ...
Ver detalles -
How to Debug the Expansion Valve of Low Temperature Freezer?
1092The effective operation of low temperature freezer is relevant to the needed refrigerating effect. It is crucial to correct expansion valve if better cooling effect is wanted. So, how to debug the expansion valve of low temperature freezer?During ...
Ver detalles -
Sistema de control de temperatura de la máquina de recubrimiento por deposición de vapor-sistema de agua de refrigeración
1132El objetivo principal de la máquina de recubrimiento por deposición de vapor es llevar a cabo experimentos científicos e investigaciones sobre el proceso de formación de películas. Se compone de cámara de reacción de tubo de cuarzo, armario de horno de blindaje térmico, sistema de control eléctrico, vacío...
Ver detalles -
Aproximación a LNEYA 5 Productos principales
1856Industrial Chiller:Industrial Chiller varies from dynamic temp. control systems, heating and cooling machine, water/air cooled chiller and heating circulator.Dynamic temp. control systems.All the industrial chiller differ sometimes considerably i...
Ver detalles