Analysis of Common Faults in New Energy Vehicle Power Battery Test System
If the new energy vehicle power battery pack leaks, the general fault manifestation mode: the meter OK light does not light, the meter prompts to check the power system, the high voltage system leakage fault, disconnect the battery pack and the body all connections (positive and negative lead, sampling line interface) .
Close the maintenance switch assembly, multimeter test battery pack parameters: closed maintenance switch, use a multimeter to measure the total voltage of the power battery V, use a multimeter to measure the positive and body voltage V1, use a multimeter to measure the negative and body voltage V2, multimeter pen replacement Parallel fixed value resistance meter pen, and set the gear position to the resistance file, measure the fixed value resistance value R, multimeter table position back to the DC voltage file, measure the parallel resistance, the positive pole and the body voltage V1, measure the parallel resistance, the negative pole and the body After the voltage V2 is measured, disconnect the maintenance switch.

If a new energy vehicle battery encounters a temperature-type fault, it means that the vehicle does not have an OK file. The instrument panel indicates that the power battery temperature is too high. After a temperature alarm occurs, the manager, the wiring harness, and the like need to be excluded (replacement manager, The manager and the battery pack are connected to the sampling harness); if the fault persists after the replacement, it is judged that the power battery is faulty.
Wuxi Guanya New Energy Battery Cooling Test System Platform reminds that if the power battery is seriously unbalanced, check the vehicle for full charge and charge, and switch BMS test 80%, 50%, 0% single-cell battery voltage data flow, observe and compare If the low battery voltage is the same, the fault still replaces the power battery.
If there are other faults in the battery pack in the automotive power battery test system, it is recommended to contact the battery manufacturer for processing.
Recomendaciones relacionadas
-
Motor test bench test and temperature system for vehicle components
1347All vehicle components must undergo rigorous testing, but safety programs must undergo more stringent durability and terminal testing. Many physical methods can be used to load the motor, but the small motor test bench is favored for its high spee...
Ver detalles -
Unidad de control de la temperatura del reactor TCU con bucle de control PID
1124LNEYA reaction kettle temperature control unit tcu adopts PID control loop, which has certain applications in many fields. The reaction kettle temperature control unit tcu of PID control loop adopts fully closed cycle refrigeration system, with fa...
Ver detalles -
Cooling water circulator for BMS testing of liquid-cooled battery packs
977As the weather temperature gradually increases, the use of liquid-cooled battery pack BMS test cooling water circulators also gradually reaches its peak. Liquid-cooled battery pack BMS test cooling water circulators have rated power ranging from s...
Ver detalles -
Introduction to the setting and operation of the ethylene glycol chiller at minus 30℃
967The minus 30 degree ethylene glycol chiller is a single-fluid low-temperature refrigeration unit with compressor refrigeration. How should the user set it better when operating it? 1. Automatic logout time Automatic logout means that when a user ...