What Are The Characteristics Of The Reactor Heating System?
Wuxi Guanya LNEYA reactor heating system The liquid circulation of the whole system is closed, the system has an expansion vessel, the expansion vessel and the liquid circulation are adiabatic, do not participate in the liquid circulation, only the mechanical connection, regardless of the temperature of the liquid circulation is high temperature Or the medium in the low temperature expansion vessel is below 60 degrees. The whole liquid circulation is a closed system. There is no water vapor absorption at low temperature, no oil mist is generated at high temperature, and the heat transfer oil can have a wide working temperature. The same machine, the same heat medium can achieve -95 degrees to 200 degrees. temperature. Cooling capacity 1KW~ 80KW range No mechanical and electronic valves are used in the entire circulation system.

Features of Wuxi Guanya LNEYA reactor heating system:
1. Equipped with heating and cooling integrated container, the heat exchange area is large, the rate of heating and cooling is very fast, and the demand for heat transfer oil is relatively small. Continuous temperature rise and fall can be achieved. The refrigeration heat exchanger adopts a high-force plate heat exchanger, which has high heat exchange efficiency and small floor space. The whole cycle is closed, no oil mist is volatilized at high temperature, the heat transfer oil will not be oxidized and browned; the water vapor in the air will not be absorbed at low temperature; the life of the heat transfer oil is prolonged.
2. Temperature adaptive control, adaptive control system in the process of control technology (such as chemical reaction process), continuously adjust the PID parameters to give the process the best control temperature and response time, this process is through effective multi-directional The rate of temperature, temperature change and temperature change is measured. Features PT100 with correct external and internal circulation temperature probes.
Con función de autodiagnóstico, protección contra sobrecarga del congelador, interruptores de alta presión, relés de sobrecarga, dispositivo de protección térmica y otras funciones de seguridad, y garantizar plenamente el uso de la seguridad.
4. Use CFC-free and HCFE refrigerants.
5. Precise control of the speed of chemical reactions.
6.Program function series. Nonlinear and linear temperature jump function. Each step of the program includes the control of the external loop program, which is controlled by the PLC controller computer.
7.Automatic diagnosis and system monitoring function series. Through the PLC touch screen controller, the computer implements monitoring and display detailed system information.
Recomendaciones relacionadas
-
Sistema de control de temperatura para calentar líquido a 100℃ y enfriarlo a 30℃.
1058En cuanto a los métodos de calefacción, los más comunes son la calefacción por vapor, la calefacción por aceite térmico, etc. El calentamiento por vapor puede requerir calderas, adecuadas para fábricas con suministro de vapor; el aceite térmico es adecuado para altas temperaturas y requ...
Ver detalles -
How to Solve the Problem of Compressor Noise in Industrial Low Temperature Chiller?
1158In industrial low temperature chiller, compressor operation will produce noise, but only thedifference of sound size. Generally speaking, there will be some problems if the noise is too large. So, how to solve the problem of compressor noise?Gener...
Ver detalles -
-
Cómo elegir un baño refrigerante y puntos de mantenimiento
1035El llamado termostato de refrigeración, como su nombre indica, es un dispositivo que proporciona una temperatura constante. En general, todo el mundo lo llama también incubadora, termostato, etc. Sólo se sabe lo suficiente para utilizar mejor el baño refrigerante. Termostato de refrigeració...
Ver detalles