Get in touch with our chiller Heaters experts
Contacte con LNEYA®
Envíenos su solicitud y nos pondremos en contacto con usted en 24 horas
Buscar en toda la estación
Dynamic Temperture Control System SUNDI series
Temp range -100℃~250℃ Temp accuracy ±0.5℃
Chiller Heaters Combo Video
The fully closed cycle design eliminates medium volatilization and moisture absorption, and supports low-temperature automatic refilling to ensure long-term stable operation of the system.
In addition, the SUNDI series process chiller adopts ultra-high temperature cooling technology, which can quickly cool directly from 300℃, and is equipped with magnetic variable frequency pumps and variable frequency compressors to achieve energy saving and silence.
Capacidad de refrigeración 2,1 kW~15 kW
Potencia de calefacción 3,5 kW~15 kW
Potencia frigorífica 1,8 kW~200 kW
Potencia de calefacción 3,5 kW~200 kW
Potencia frigorífica 0,25 kW~200 kW
Potencia de calefacción 2,5 kW~200 kW
Potencia frigorífica 0,25 kW~60 kW
Potencia de calefacción 2,5 kW~60 kW
Cooling capacity 0.3kW~80kW
Heating power 3kW~80kW
Precisión a media temperatura ±0,5℃
Precisión de la temperatura del material ±1℃
Cooling capacity 0.5kW~80kW
Heating power 5.5kW~80kW
Precisión a media temperatura ±0,5℃
Precisión de la temperatura del material ±1℃
Cooling capacity 0.7kW~80kW
Heating power 5.5kW~80kW
Precisión a media temperatura ±0,5℃
Precisión de la temperatura del material ±1℃
Cooling capacity 0.4kW~1.5kW
Heating power 2kW
Precisión a media temperatura ±0,5℃
Precisión de la temperatura del material ±1℃
Chiller Heater Applications
At present, SUNDI series chiller-heater has been widely used in chemical reactor temperature control, pharmaceutical biological fermentation, semiconductor testing and other scenarios to ensure the accuracy of temperature and repeatability of results during experiments and production.
In temperature-sensitive fields such as semiconductor manufacturing, biopharmaceuticals, and new energy battery testing, the process challenges of alternating hot and cold are everywhere. If your process flow includes the following, then you definitely need a chiller heater.
Accelerate material aging and provide extreme high temperature and low temperature environment for material durability and reliability testing.
Compact structure, precise adjustment of distillation temperature, suitable for small-scale laboratory operation, energy-saving and efficient, easy to operate, and highly flexible.
Adapt to the vacuum environment to stabilize the output temperature at the set temperature and avoid thermal fluctuation interference.
2.Fully enclosed design
The SUNDI industrial chiller system adopts a fully enclosed pipe design, which does not absorb moisture at low temperatures and does not volatilize the medium at high temperatures, effectively extending the service life of the heat transfer liquid and reducing operating costs.
3.Magnetic drive pump
The SUNDI dynamic temperature control system chiller is equipped with a magnetic drive pump, which does not use mechanical seals, so there is no shaft seal leakage problem, and you don’t have to worry about the safety hazards caused by leakage. At the same time, we can also use variable frequency control according to your needs.
Why Choose LNEYA® ?
Get in touch with our chiller Heaters experts
Contacte con LNEYA®
Envíenos su solicitud y nos pondremos en contacto con usted en 24 horas
WeChat/Phone
86 18914253067
+86 18914253067
Dirección de correo electrónico
market@lneya.com