Industrial heating systems

  • The temperature control accuracy is around 0.5℃.
  • Employ a fuzzy PID adaptive controller
  • The temperature of the heat-conducting medium is fed back through the Pt100 sensor.
  • High-temperature cooling process, continuous heating and cooling can be achieved.
  • A fully enclosed system is equipped with an expansion vessel, which is insulated and does not participate in the liquid circulation.

Lneya’s UC/LY series is an economic type of heating circulators. UC/LY series utilizes industrial heating system. Its maximum cooling capacity is 130kW(UC-A13030N). There are options for air cooling and water cooling available. Lneya’s UC-XX30 series temperature range is +50℃~+300℃, and LY/UC-50XX series temperature range is +50℃~+170℃. UC series can only control the temperature of the heat transfer medium.

Industrial heating systems

50°C

más bajo

300°C

Más alto

±0.5°C

Precisión del control de temperatura


Modelo UC-5530N UC-7530N UC-A1030N UC-A1530N UC-A2530N UC-A3830N UC-A6030N UC-A9530N UC-A13030N
Temp  range 50℃~300℃
Temp control Control de la temperatura de salida del fluido caloportador
Heating power KW 5,5 kW 7,5 kW 10kW 15 kW 25 kW 38 kW 60 kW 95 kW 130 kW
Refrigeración
Capacity
kW at
300℃ 5,5 kW 7,5 kW 10kW 15 kW 25 kW 38 kW 60 kW 95 kW 130 kW
200℃ 5..5kW 7,5 kW 10kW 13kW 25 kW 38 kW 60 kW 95 kW 130 kW
100℃ 4kW 5kW 7kW 12kW 20 kW 30 kW 48 kW 76 kW 100 kW
65℃ 1,8 kW 2,2 kW 3kW 5kW 8,5 kW 12kW 19 kW 30 kW 40 kW
Criculation pump
flow
Máx35L/min 1,2BAR Max50L/min 1.2BAR Max50L/min 1.2BAR Máx110L/min 1,5BAR Máx150L/min 1,5BAR Máx200L/min 1,5BAR Máx250L/min 2,5BAR Máx400L/min 2,5BAR Máx400L/min 2,5BAR
Dimensión cm 40*70*130 45*70*160 45*70*160 70*100*175 70*100*175 80*120*185 150*100*185 200*145*205 200*145*205
Power max
AC 380V 50HZ
7kW 9kW 12kW 17 kW 28 kW 41 kW 65 kW 101 kW 136 kW
Opcional 220V 60HZ three phase,440V~460V 80HZ three phase

Heat apparatus: provide a heat source and convert electrical energy into thermal energy, and heat the heat-conducting medium.


Circulating Pump: the driving heat-conducting medium circulates within the system to ensure that the heat is uniformly transferred to the target equipment (such as reaction vessels, microchannel reactors, etc.). The circulating pump is resistant to high temperature and corrosion, and its flow rate can be adjusted.

Our standard machine will not alarm. If you have any requirements, we can provide optional configurations.

ProblemsPossible CausesSolutions
Large temperature fluctuationPt100 sensor failureCalibrate or replace the sensor
Abnormal circulation pumpPipe blockage/voltage instabilityClean the pipes or check the power supply
High temperature alarmInsufficient cooling/overload of heaterCheck the cooling water flow or reduce the load

*
*