Fallos comunes y análisis de causas de enfriadoras refrigeradas por aire
During the use of air-cooled chiller equipment, it is inevitable to encounter some common faults. Users need to understand the possible causes of faults and make corresponding solutions in time, so as to make the production and operation more stable. So, what are the common faults of air-cooled chillers?

1. The inlet and outlet water temperature difference is small
When users encounter a small difference in inlet and outlet water temperature when using air-cooled chillers, the general reasons are as follows.
First, the output cooling capacity of the chiller is small, such as the equipment itself is faulty or not fully loaded. We suggest that in these cases, the user can make a preliminary judgment by observing the operating current and other parameters of the chiller.
Second, the heat transfer effect of the equipment is not good. For example, the scaling of the heat transfer pipe is serious, which affects the heat exchange of the chiller. Users can judge by observing the heat transfer temperature difference between the water temperature and the evaporation temperature.
Third, the water flow is too large. Users can judge by observing the inlet and outlet water pressure difference of the evaporator and the running current of the water pump. In addition, if the above problems are eliminated, the user can check whether the sensor or thermometer is accurate.
2. Communication failure
It is understood that the computer controller controls each module through the communication line and the general interface board. The main cause of communication failure is poor contact or open circuit of the communication line, especially poor contact caused by damp and oxidation of the interface. In addition, failure of unit electronic board or general interface board, improper selection of address dial switch and power failure can cause communication failure.
3. High voltage fault
When the discharge pressure of the compressor is too high, it is easy to cause the action of the high-voltage protection relay. If the pressure is too high for a long time, it will lead to excessive operating current of the compressor, easy to burn the motor, and easy to damage the valve plate at the exhaust port of the compressor.
So, under what circumstances will high voltage fault occur? It mainly includes: high cooling water temperature and poor condensation effect. The cooling water flow is insufficient to reach the rated water flow. Condenser fouling or blockage. Excessive refrigerant charge. The refrigerant is mixed with non condensable gases such as air and nitrogen. False alarm caused by electrical failure.
4. Low voltage fault
When the suction pressure of the compressor is too low, it will cause the low pressure protection relay to act. It is understood that the causes of low pressure failure are: insufficient refrigerant or leakage. Insufficient refrigerant water flow. Blocked evaporator and poor heat exchange. False alarm caused by electrical failure. The outside temperature is low.
In addition to understanding the above fault causes, users should also pay attention to the maintenance of the equipment after using the chiller, so as to ensure the extension of the service life and stable operation of the equipment.
Recomendaciones relacionadas
-
Noise description of common faults in high and low temperature integrated equipment
1199High-low temperature integrated machine equipment may cause malfunction due to improper operation, then how to deal with noise failure of the equipment, and then analyze the noise too high. The suction of high and low temperature integrated equipm...
Ver detalles -
¿Cómo elegir el precio del sistema semiconductor de temperatura constante?
1031Now, it can be said that most of the industrial production of various types require a semiconductor thermostat system to provide professional refrigeration, and an efficient semiconductor constant temperature system can provide great help for vari...
Ver detalles -
Description of LNEYA industrial ultra-low temperature freezer
1244LNEYA industrial ultra-low temperature freezer is mainly used in industrial cold treatment to precipitate uniform, fine and dispersed carbides on the metal structure matrix. The appearance of such a carbide will bring about a significant increase ...
Ver detalles -
Fallo del compresor del sistema de control de refrigeración causado por la presión del aceite
978If there is no oil pressure in the refrigeration control system, check the oil pump piping system connection for oil leakage or blockage. If the connection is loose, the joint should be tightened. If it is blocked, the oil pipeline should be clear...
Ver detalles