Troubleshoot the main points of failure of the high and low temperature cooling system
When the industrial high and low temperature cooling system is in use, what is the general reason if the temperature cannot drop down? How should we deal with such failures?
Let’s first analyze the principles and methods of industrial cooling. The circulating heat transfer medium is different. Generally, the high and low temperature cooling system industry mostly uses direct cooling, while indirect cooling is used, with plate heat exchangers or oil coolers installed inside. In other devices, the heat medium and cooling water source in the system exchange heat in the heat exchanger to reduce the temperature of the medium.
The temperature of the high and low temperature cooling system cannot be reduced. Generally, we conduct inspection and maintenance from the following aspects:
1. The cooling solenoid valve is damaged: it is necessary to check whether the solenoid valve coil can work normally, if it is damaged, it needs to be replaced; the panel does not output a cooling signal, carefully check the circuit or use the component replacement method to check.
2. Circuit failure: Check the circuit part of the system, the cooling water inlet or outlet pipeline is blocked: check whether the valve in the cooling water pipeline is fully opened, and ensure that the flow and pressure of the cooling water are sufficient, and the heating contactor is stuck, Always heating: observe the pull-in state of the contactor, and worsen damaged electrical parts.
In addition to troubleshooting the above two possible causes of failure, we also need to check whether the cooling plate is replaced or the cooling exchanger is blocked.
The advantage of using indirect cooling is that it has high temperature control accuracy and strong adaptability. It can be applied to the temperature control of high and low temperature cooling system industries. And because the heat transfer medium is cooled first, the cooling impact on the temperature control equipment is relatively small. Of course The disadvantage is that the cooling speed is relatively slow, and the price is more expensive than direct cooling.
Recomendaciones relacionadas
-
Small desktop sealed chiller troubleshooting solution
1477Small desktop sealed chillers will have more or less failures after long-term use, so how can the compressor be solved if there are some faults? LNEYA specializes in the development and production of small desktop sealed chillers with a temperatur...
Ver detalles -
Diseño y tecnología de pruebas de venta de cámaras ambientales de alta temperatura
21281. Selección de la temperatura (1) Las zonas climáticas de la región; Si el producto está expuesto al entorno de radiación solar cerca del dispositivo de calentamiento; Aire circundante, radiación solar y formas de transferencia de calor de los dispositivos de calentamiento a los productos;...
Ver detalles -
-45 °C freezer manufacturers analyze compressor burnout detection and repair methods
1474In the -45 ° C freezer, the compressor is one of the more important components, the manufacturer Wuxi Guanya (LNEYA) tells everyone that once the compressor fails, it needs timely inspection and maintenance, then how to check the work and maintena...
Ver detalles -
You Should Know Something About Ultra Low Temperature Freezer
1294Ultra low temperature freezer is an indispensable cryogenic storage equipment in the field of life sciences and biopharmaceuticals. It can be used to store cells, tissues, test samples, vaccines, active enzymes, strains, plasmids, viruses, bacteri...
Ver detalles
LNEYA Enfriadoras industriales Fabricante Proveedor