Análisis del principio de funcionamiento del termostato de refrigeración y calefacción
Con el continuo desarrollo de la tecnología, más y más equipos de refrigeración ha aparecido en nuestras vidas, tales como: circuladores de refrigeración y calefacción, de hecho, no son ordinarios, son notables equipos de refrigeración. Los equipos de refrigeraci...
The refrigeration heating circulator uses a limited amount of refrigerant in a closed refrigeration system to repeatedly compress, condense, expand, and evaporate the refrigerant, and continuously absorbs heat and vaporizes at the evaporator to perform cooling and cooling. The process of cooling the object to below ambient temperature and maintaining the low temperature by the refrigerant moving the heat from a low temperature object (such as a cold storage) to a high temperature object is achieved by using a refrigeration device.
An important parameter of the refrigeración calefacción circulador is the refrigeration coefficient, also known as the operating coefficient of the refrigeration unit, indicated by the symbol COP. The refrigeration heating circulator Xiaobian tells everyone that at a certain ambient temperature, the lower the cold storage temperature, the smaller the cooling coefficient.
So, what are its advantages?
The entire liquid circulation is hermetic, with an expansion vessel, the expansion vessel and the liquid circulation are adiabatic, do not participate in the liquid circulation, but are mechanically connected, regardless of whether the temperature of the liquid circulation is high temperature or the medium in the low temperature expansion vessel is less than 60 degrees. .
The entire liquid circulation is a closed system. There is no absorption of water vapor at low temperatures. There is no oil mist at high temperatures. The heat transfer oil can have a wide operating temperature; mechanical and electronic valves are not used in the entire circulation system.
Next, let’s look at the refrigeration principle of the refrigeration heating circulator.
Compressed air refrigeration cycle
Since the air temperature heating and the constant temperature heat removal are not easy to achieve, it cannot be operated in the reverse cycle. In the compressed air refrigeration cycle, two constant pressure processes are used to replace the two constant temperature processes of the reverse cycle, so it can be regarded as a reverse cycle. In engineering applications, the compressor can be piston or impeller.
Compressed vapor refrigeration cycle
The reverse refrigeration cycle of compressed steam can be theoretically achieved, but a state of too low dryness will occur, which is not conducive to the compression of two-phase materials. Refrigeration heating circulators, which tell you that in order to avoid adverse factors, increase cooling efficiency and simplify equipment, throttle valves (or expansion valves) are often used instead of expanders in practical applications.
The compressed vapor refrigeration cycle uses a low-boiling substance as a refrigerant, and utilizes the constant pressure in the wet vapor zone to determine the temperature, and the constant pressure gasification endothermic refrigeration at a low temperature can overcome some of the disadvantages of the above-mentioned compressed air and regenerative compressed air circulation.
Absorption refrigeration cycle
The absorption refrigeration cycle utilizes the different solubility characteristics of the refrigerant at different temperatures in the solution, so that the refrigerant is absorbed by the absorbent (ie solvent) at a lower temperature and pressure, while at the same time making it at a higher temperature and pressure. Evaporate from the solution and complete the cycle for refrigeration purposes.
Recomendaciones relacionadas
-
LNEYA: Concéntrate en diseñar cada detalle para crear brillantes
1905LNEYA utilizes the outstanding talents in the field of refrigeration and heating temperature control, and has a strong technical background. It has a well-known high-end R&D team in the industry. It is a high-end R&D and application team f...
Ver detalles -
Treatment of organic waste gas by condensation method
1967Condensation treatment of organic waste gas equipment should pay attention to its performance when selecting. It is very necessary to choose high-performance condensation method to treat organic waste gas. So what is the use of organic waste gas f...
Ver detalles -
What should I pay attention to when using the reactor for chilling and cooling?
1723When using the reactor chilling and cooling and cooling device, users need to pay attention to their refrigeration and heating operations. Pay attention to the operation within a reasonable temperature range to avoid excessive temperature and pres...
Ver detalles -
Installation Requirements For Ethylene Glycol Cryo Chillers
1546After the purchase of ethylene glycol cryo chillers with professional manufacturers Wuxi Guanya, installation requirements will be sent to the hands of users with the equipment. So, what needs to be paid attention to during the installation of eth...
Ver detalles