What are the components that improve the performance of industrial chillers?
Industrial chillers are indispensable equipment in LNEYA production. With its normal operation, we will have better work efficiency and higher product quality. The refrigeration system of an industrial chiller is mainly composed of four core components: compressor, condenser, expansion valve and evaporator. On this basis, in order to improve the performance of industrial chillers, there are usually some auxiliary components.

(1) Compressors for industrial chillers:
It is the core of the entire chiller. Its quality is enough to affect the quality of a machine, and even the length of its lifespan. The compressor is the power source to ensure refrigeration. The compressor is used to increase the refrigeration pressure in the system, so that the refrigerant circulates in the refrigeration system to achieve the purpose of refrigeration. Common compressor types are open, semi-hermetic and fully-hermetic. Generally, the chiller with chilled water above 0°C adopts a fully hermetic compressor. If the chilled water is below 0°C, the low-temperature chiller uses a semi-hermetic compressor, while the open type is generally used in the refrigeration system with ammonia as the refrigerant.
(2) Condenser of industrial chiller:
It is the high temperature and high pressure Freon of the refrigeration system. After coming out of the compressor, it enters the condenser, releasing a lot of heat to the cooling medium, cooling and liquefying. There are three common types: water-cooled, air-cooled and evaporative. We mainly talk about water-cooled condensers. In a water-cooled condenser, the heat given off by the refrigerant is carried away by the cooling water. The cooling water can be flowed once or recycled. When using circulating water, cooling towers or cold pools are required. Water-cooled condensers have shell and tube, casing, immersion and other structural forms.
(3) Industrial chiller evaporator:
When the freon liquid in the refrigeration system enters the expansion valve and is sent to the evaporator, it belongs to the vaporization process. At this time, a large amount of heat needs to be absorbed, so that the temperature of the cooled medium is gradually lowered, so as to achieve the effect of cooling and cooling. According to the type of cooling medium, it is divided into two categories: cooling liquid (water) evaporator and cooling air evaporator.
(4) Industrial chiller expansion valve:
It is a throttling and pressure-reducing component that reduces the condensation pressure of the refrigerant to the evaporating pressure, so it is an essential component in the refrigeration system. It is called the four major components of the refrigeration system together with the compressor, the evaporator and the condenser.
Recomendaciones relacionadas
-
The relationship between vocs adsorption condensing equipment price and configuration
958The quality of vocs adsorption condensing equipment must be guaranteed. This can be used with confidence. The reason for the power consumption may also be that the gas inhaled by the BITZER compressor allows a certain degree of superheat, but the ...
Ver detalles -
Mantenimiento rutinario de los equipos de control de temperatura de los reactores múltiples tcu
930TCU multi-reactor temperature control equipment is widely used in research departments such as petroleum, chemical, electronic instruments, physics, chemistry, bioengineering, physical property testing and chemical analysis, colleges and universi...
Ver detalles -
Instrucciones de procesamiento de la unidad de recuperación de condensación de gas Vocs
1306Con la inspección continua de la protección del medio ambiente, el dispositivo de recuperación de condensación de gas VOCS de Wuxi LNEYA también ha recibido la atención continua del público. La mayoría de las industrias químicas, farmacéuticas e industriales están tratando urgentemente con...
Ver detalles -
El sistema de refrigeración del motor comprueba el efecto de la temperatura de condensación
1266El sistema de refrigeración del motor prueba el condensador. En condiciones normales, la primera mitad de la tubería de calor está muy caliente, y su temperatura tiene un lento y lento descenso gradual en el balance de potencia. La sensibilidad térmica de la segunda mitad del hea...
Ver detalles