Consejos de mantenimiento diario para enfriadoras de recirculación a temperatura ultrabaja?
To ensure normal operation of the enfriadores de recirculación a temperatura ultrabaja after startup, it must be ensured that the condenser of the ultra low temperature recirculating chiller has good heat dissipation, otherwise the high temperature protection device of the ultra-low temperature circulating chiller will stop and even break down due to the condensing temperature and the corresponding condensing pressure, causing a malfunction. The cold water in the evaporator should be circulated, otherwise the cold water temperature will be low, causing the cold water temperature protection device to stop and break down, or because the evaporation temperature and the corresponding evaporation pressure are too low, the low-pressure protection device of the chiller will stop and even cause the cold water in the evaporator freezes and damages the equipment.
1. In order to ensure the good performance of the unit, please keep the chiller in a good environment, with good ventilation and low temperature.
2. After turning off the compressor, turn off the cooling fan.
3. Every 6 months or when the performance of the chiller drops, please clean the condenser and check that the operating valve is in a normal state.
4. The optimum working pressure of the condenser should be less than 1.5MPa. Check and clean the condenser frequently to maintain the best performance of the machine.
5. For air-cooled machines, ensure that the machine is well ventilated and that the condenser is regularly maintained.
6. If it is not used for a long time, sometimes the pump impeller will be blocked by the sediment, so turn the pump cooling fan by hand before using the machine.
7. During the work, the parameters should be recorded in a timely and correct manner.
8. If there is an alarm stop during the operation, the relevant personnel should be notified in time to check the unit. If the fault cannot be eliminated, the factory can be directly contacted.
9. During the operation of the unit, it is strictly forbidden to short sub the water flow switch to avoid freezing the water pipe.
10. Machine rooms should be equipped with appropriate safety equipment and maintenance testing tools, such as pressure gauges, thermometers, etc., and the tools should be stored in a fixed position.
Recomendaciones relacionadas
-
Cómo solucionar el problema de que el frigorífico de 10 CV no puede producir agua
1637Wuxi guanya tiene congelador de placa fría para la venta para el tratamiento de frío industrial.Bueno,¿cómo resolver el problema de la falla de salida de agua de 10hp congelador de placa fría?Por lo tanto,he...
Ver detalles -
¿Cuáles son los principales usos de la unidad de calefacción y refrigeración del reactor?
1639El dispositivo de calentamiento y enfriamiento del reactor es adecuado para metales de alta pureza, purificación de sustancias raras, simulación de entornos de laboratorio, pulverización catódica por magnetrón, revestimiento al vacío y otras industrias. Las grandes unidades de bomba criogénica pueden proporcionar un e...
Ver detalles -
Aplicaciones industriales de las enfriadoras de agua
1475Chillers, commonly known as freezers, chillers, chillers, chillers, chillers, etc., are widely used in various industries, so the names are numerous. The principle of its nature is a versatile cooling device that removes liquid vapor through a com...
Ver detalles -
Selección y mantenimiento de refrigeradores de temperatura ultrabaja
1397Today, a customer came to inquire about our need for a small laboratory water chiller. The specific working condition is to reduce the materials in the 20L stainless steel reactor from normal temperature to minus 30 ℃ in more than one hour. This p...
Ver detalles