Tips for Leakage Detection of Low Temperature Freezer
Soaking leakage detection
The sensibility of soaking leakage detection is higher than bubble test,which is usually applied for small Freon freezer unit. When using it, the equipment prohibited from contacting water in the system should be discharged, like all kinds of relays and electrical control device. Taking advantage of warm water during the bubble test, because its surface tension is smaller than cold water, forming bubbles more easily. As an editor of Low Temperature Freezer, I want to tell you that the leakage point will be discovered simply if accompanied by intense light source. After the completion of soaking leakage detection, the surface ought to be dried with compressed air, preventing the metal from corrosion.
Halide torch and its leakage detection
These are the specialized devices for detecting the Freon freezer unit system. When Freon refrigerating fluid encounters hot cooper parts, different colored flames will be casted for F2, C12 and Br contain the elements of halogen, helping find out the leaking point.
Vacuum leak test
When freezer unit system passes the pressure leakage detection, it should also go through the vacuum leak test since some pasts exist one-way leaker. Only pressure and vacuum leakage detection both conform to the standard can the leakproofness of cooling system can be ensured. Besides, the system is evacuated, so can water at the same time , esped dcially the Freon system. Therefore, evacuation and desiccation play essential roles in debugging the unit.
Should the uses for low temperature freezer be understood, the users will have a better try! Visit LNEYA to know more about low temperature freezer price.
Recomendaciones relacionadas
-
Instrucciones de preparación de la serie TES-5 dedicada a la prueba de chips
1603La serie TES-5 para pruebas de chips se utiliza para pruebas de componentes electrónicos. Cómo detectar con precisión el chip es muy importante. Entonces, ¿cuánto sabe sobre la preparación de la prueba de la serie TES-5 para la prueba de chips? Antes de iniciar la serie TES-5...
Ver detalles -
¿Qué debo hacer si los compresores de la enfriadora 30p Refrigerated se sobrecalientan?
2088When users purchase 30p Refrigerated chiller, they understand the internal configuration. The compressor is an important accessory in 30p Refrigerated chiller. If it overheats, 30p Refrigerated chiller will be unavailable, then 30p Refrigerated ch...
Ver detalles -
La importancia del control de la temperatura para procesar plantas de cannabis
1496La legalización del cáñamo industrial en Europa, América y otros países ha aumentado la demanda de equipos para el procesamiento del cáñamo. Con el tiempo, el cannabis se presenta en forma de extracto de CBD. Con el fin de convertir la planta en un concentrado para medic...
Ver detalles -
Cooling method for laboratory evaporative instruments in operation
1425Choosing the right cooling method for an evaporation experiment can have an unimaginable impact on overall system performance, economy, and efficiency. It is necessary to purchase cooling water circulation machine as supporting equipment. When pu...
Ver detalles
LNEYA Enfriadoras industriales Fabricante Proveedor