Manufacturer explains what are the influences of the oil level and oil difference of the chiller?
The chiller manufacturer tells everyone that in addition to the refrigeration system, the lubricating oil system is also an important part, with its own oil reservoir and special oil cooler. Therefore, we must understand the influence of the oil level and oil difference of the chiller?
Oil level
It refers to the level of lubricating oil in the oil storage container. The oil storage containers of low-temperature chillers are equipped with oil level display devices. Generally, it is stipulated that the oil level in the oil storage container should be 5mm above and below the central horizontal line of the sight glass. The purpose of specifying the oil level is to ensure that when the oil pump is working, the amount of oil required to form an oil circulation is sufficient. If the oil level is too low, it is easy to cause insufficient oil pumps, which may cause operation failures or damage the equipment.
Oil pressure difference
It is the guarantee that lubricating oil needs to overcome the flow resistance when it flows to various working parts in the pipeline of the oil system under the drive of the oil pump. Without sufficient oil pressure difference, it is impossible to guarantee that the lubrication system of cold and low temperature chiller has sufficient lubrication and cooling oil and the power required to drive the energy regulating device. Therefore, the low temperature chiller manufacturer reminds that the oil pressure difference of the oil system It must be ensured in a reasonable range so that the moving parts of the unit can be fully lubricated and cooled, and the energy adjustment device can be manipulated flexibly.
Oil temperature
Oil temperature refers to the temperature of lubricating oil when the chiller is working. The oil temperature has an important influence on the viscosity of the lubricating oil. If the oil temperature is too low, the viscosity of the oil will increase, the fluidity will decrease, and it is not easy to form a uniform oil film, so the expected lubrication effect cannot be achieved, and it will also cause the oil flow speed to decrease, reduce the lubrication volume, and the power consumption of the oil pump. Increase; if the oil temperature is too high, the viscosity of the oil will decrease, and the oil film will not reach a certain thickness, making it difficult for the running parts to withstand the necessary working pressure, causing deterioration of the lubrication condition, aggravation of the moving parts, and failure of the chiller.
So let’s not say much, the chiller manufacturer believes that everyone also understands the impact of oil level and oil difference. In order to better use the chiller, you still need to understand these operating points carefully!
Recomendaciones relacionadas
-
Volar por sueño, crear mayor gloria, [Wuxi Guanya LNEYA] ceremonia anual terminó con éxito
2310Inadvertently2019 has passedThis yearThanks to everyone for the trust and support of Guanya LNEYA Eye-catching gloryFrom every step of the solidThank you all the wayDream-seeking career2020 Let us continue to work together for a win-win sit...
Ver detalles -
Professional introduction and application of cooling circulating water machine
1605The cooling water machine (the chiller, also known as the chiller) is an air-cooled water circulation device that does not require a cold water tower. It is a compressor-cooled design that is designed for machines, scientific instruments, or produ...
Ver detalles -
Sistema de control de temperatura de la máquina de recubrimiento por deposición de vapor-sistema de agua de refrigeración
1757El objetivo principal de la máquina de recubrimiento por deposición de vapor es llevar a cabo experimentos científicos e investigaciones sobre el proceso de formación de películas. Se compone de cámara de reacción de tubo de cuarzo, armario de horno de blindaje térmico, sistema de control eléctrico, vacío...
Ver detalles -
How To Choose The Equipment For The Reactor?
1332The choice of equipment for the reactor needs to be measured by the following points: 1. Heating method: Generally, the electric heating should be greater than or equal to 3 tons, and in the case of the outer half pipe; less than or equal to 3 to...
Ver detalles
LNEYA Enfriadoras industriales Fabricante Proveedor