How to deal with the excess refrigerant in 3p freezers?
When the three freezers are being serviced, it is necessary to add refrigerant regularly, but the manufacturer of LNEYA reminds everyone that once the refrigerant is added excessively, it will cause a series of problems.
According to the instructions of the 3p freezers, it is required to fill the refrigerant to maintain normal operation. If the number of refrigerants added by the company is very high during the operation of the 3p freezers, the higher the operating power, the stable operation of the equipment. The lower the sex, the more serious the failure of the equipment, the safety and stability of the equipment is directly endangered, and even the equipment can not meet the cooling demand of the space even if it consumes a lot of energy.
If the amount of refrigerant inside the three refrigerators is relatively large, while the equipment can be operated, although the temperature of the environment can be lowered in a short time, the running stability of the equipment is easily affected after the running time of the equipment increases. When the equipment can not run stably, the equipment often has some unexplained failures, endangering the service life of 3p freezers, and even causing equipment downtime, which seriously affects the normal use of the enterprise.
The maintenance of 3p freezers is not simple. Especially for the maintenance of the refrigeration system, even if the equipment is not faulty, in the case of normal use of the equipment, there will still be problems such as refrigerant leakage in the 3p freezers. The company can timely analyze whether the refrigerant has a leak failure, and keep the freezer within the normal pressure range, which can improve the operating efficiency of the three freezers. Even if the space used is very large, the equipment can also quickly reduce the ambient temperature and effectively meet the requirements. The low temperature demand of the enterprise provides conditions for improving the production efficiency of the enterprise.
If the refrigerant of 3p freezers is excessively added, it may cause more faults. Therefore, users should pay attention when adding refrigerants themselves, and try not to add excessive refrigerant, which causes the refrigerator to be unavailable and faults to occur.
Recomendaciones relacionadas
-
The Reasons of Frosting on Ultra low Temperature Recirculating Chillers
1606Frosting will appear when many users take advantage of ultra low temperature recirculating chillers, while some are not. It is confusing and whether it is relevant to refrigeration.First of all, why does ultra low temperature recirculating chiller...
Ver detalles -
What are the effects of the oil separator on the equipment analyzed by the chiller manufacturer
1379Oil separators use more accessories in thechiller refrigeration system. So as users, we need to understand where the mainimpact is in order to better use the equipment.In the configuration of the chiller, theposition of the oil separator is aft...
Ver detalles -
Maintenance knowledge of 12HP (8.9kW) low temperature chiller
1870The user can arrange the operator to learn about the daily maintenance knowledge of the 12HP (8.9kW) low temperature chiller after purchase. It can not only improve the company's product quality, improve production efficiency, but also extend the ...
Ver detalles -
-45 °C freezer manufacturers analyze compressor burnout detection and repair methods
1476In the -45 ° C freezer, the compressor is one of the more important components, the manufacturer Wuxi Guanya (LNEYA) tells everyone that once the compressor fails, it needs timely inspection and maintenance, then how to check the work and maintena...
Ver detalles
LNEYA Enfriadoras industriales Fabricante Proveedor