High and low temperature device related instrument maintenance instructions
The liquid medium should be added before the high and low temperature circulation device is used. The liquid medium generally uses more than 95% alcohol, and the liquid medium cannot be lower than the working plate 20mm. The high and low temperature circulation pump should be placed in a dry and ventilated place with a distance of 400 mm from the obstacle on the back and sides. The working power supply of the high and low temperature circulating device should be determined according to the model of the machine (technical parameter column). The power of the power supply should be greater than or equal to the total power of the instrument. The power supply must have a good “grounding” device (Note: low temperature coolant circulating pump 380v voltage There is a grounding lead on the screw on the lower left side of the instrument). After the high and low temperature circulation device is used, all the switches must be turned off before the power plug can be unplugged. The high and low temperature device manufacturers use the suction ball and the skin tube to suck the liquid.
If the high and low temperature circulation device is operated below 0 °C, the door should be avoided as much as possible. Because when the temperature is low, if the door is opened, the internal evaporator and other parts will be sealed, especially the lower the temperature, the more serious the situation is. If you must open it, you should try to shorten the opening time. When the low temperature operation is completed, it is necessary to set the temperature condition at 60 ° C for drying for about half an hour, so as not to affect the measurement time or icing phenomenon of the next working condition. The high and low temperature circulation device radiator (condenser) should be regularly maintained and kept clean. After the low-temperature operation of the high-low temperature cycle device, if there is no work at the sixth point above, it is also necessary to set the normal temperature condition so that the temperature inside the box is normal temperature when the machine is stopped, so as not to affect the icing phenomenon caused by the low temperature inside the box. And the fogging of the window glass.
The use of high and low temperature circulation devices requires frequent maintenance, and proper maintenance can prolong the service life of the high and low temperature circulation devices and stabilize the operation.

Recomendaciones relacionadas
-
Influencia del aceite de congelación en el sistema de ensayo de motores de propulsión de vehículos de nueva energía
1179El peligro del aceite refrigerante en el sistema de prueba del motor de propulsión del vehículo de nueva energía aumenta la temperatura de condensación y la presión de condensación; la transferencia de calor del condensador se deteriora. Debido a que la película de aceite producida por el aceite que entra t...
Ver detalles -
¿Cómo juzgar la calidad de la tubería de tratamiento de gases residuales de galvanoplastia?
986Generally, when purchasing the electroplating waste gas treatment equipment, it is necessary to observe the appearance of the copper tube to judge. The first is to look at the color of the copper tube. According to the type of copper tube purchase...
Ver detalles -
Cómo elegir el circulador de frío y calor adecuado?
1041El circulador de frío y calor se utiliza ampliamente en la industria farmacéutica y química para proporcionar a los usuarios una temperatura controlada, uniforme y constante de frío y calor. También puede equiparse directamente con reactores, reactores, etc. para...
Ver detalles -
Necessity Of New Energy Electric Vehicle Battery Test System
881The battery performance of new energy vehicles directly determines the experience of new energy vehicle end users. The electric vehicle battery test system needs to test the performance reliability of new energy vehicle batteries. With the develop...
Ver detalles