How Does the Low Temperature Chiller Apply to Mould Industry?
As you all know, the refrigerador de baja temperatura is widely used, especially in the mould line. So does everyone know how it works in the mould industry? If you don’t know, let’s have a look with me.
When using the refrigerador de baja temperatura to cool the mould, it usually cools the mould together with the injection machine. Generally speaking, the mould is quite a heat exchanger. Heat is transferred from melting to the mould, and then from the mould to the cooling medium for cooling. As we all know, mould forming is inseparable from cooling function. When choosing the refrigerador de baja temperatura, we should try to choose the refrigerador de baja temperatura with better quality and higher cost. The relative operating power is higher. Compared with the ordinary refrigerador de baja temperatura, it can increase certain output and obtain certain benefits in a longer period of time.
In the practical application of the refrigerador de baja temperatura and models, the temperature difference of ice water at the inlet is determined according to the requirements of products. In many cases, the temperature difference of 3-5 degrees is more ideal. The smaller the temperature difference, the larger the ice flow needed to take away the same heat. On the contrary, the smaller the ice flow needed.
Also, when using the refrigerador de baja temperatura, it is necessary to constantly check the water quality of the refrigerador de baja temperatura. Once the water quality changes over a long period of time, it will produce some corrosion phenomena. If not handled in time, it will produce scale, which can produce certain insulation effect. In serious cases, it will reduce the effect of conversion. Therefore, when configuring the refrigerador de baja temperatura, it will produce some corrosion phenomena. Water quality must be selected well. In addition, scales can be treated regularly in time or equipped with water treatment softening equipment.
In the process of using the refrigerador de baja temperatura for cooling, it is necessary to select the pressure of ice water. Another point is that the pipeline of the refrigerador de baja temperatura must be insulated and heat-insulated, otherwise it will cause the loss of cooling capacity and form condensation water on the outer wall, which will affect the use of the refrigerador de baja temperatura.
Recomendaciones relacionadas
-
Small hot and cold shock test box use note
1587Small thermal shock test chamber is non-explosion-proof product (explosion-proof needs to be customized), please do not use it in the environment with flammable or explosive gas. In order to avoid small thermal shock, the test box is faulty, pleas...
Ver detalles -
Unidad de circulación de calor de doble canal para pruebas de semiconductores
1338El ciclador de calentamiento de doble canal en pruebas de semiconductores se refiere a un dispositivo utilizado para probar dispositivos semiconductores (como semiconductores de potencia), que puede controlar simultáneamente dos canales de prueba independientes para realizar el calentamiento y el enfriamiento....
Ver detalles -
Uso de refrigeradores de tratamiento en frío para piezas mecánicas y comparación con el nitrógeno líquido
1543In the machinery manufacturing industry, the quality requirements for parts are very strict. In order to better improve the performance of machinery, improve product quality and life, a new technology-cryogenic treatment has been produced. During ...
Ver detalles -
Aplicación en la industria química farmacéutica - Control de la temperatura del reactor de calefacción
1732La industria química farmacéutica implica muchas reacciones químicas. La eficiencia del trabajo de control de temperatura del reactor de calentamiento tradicional es relativamente baja, el coste de producción es relativamente alto y el dispositivo es relativamente engorroso. Por ello ...
Ver detalles
LNEYA Enfriadoras industriales Fabricante Proveedor










