How to Deal with the Poor Dissipation of Low Temp Chillers
Low temp chiller products contribute a lot to various industrial production, and at the same time, help to improve the labor efficiency of industrial production. With the development of China’s economy and the improvement of production process requirements, low temp chillers have become an important aspect of the production cooling needs of most enterprises. With the application of low temp chillers in enterprises being more and more extensive, the problems of debugging, maintenance and maintenance of low temp chillers followed. So how to solve the problem of poor heat dissipation of low temp chillers?
Many low temp chiller products, after a period of practical operation, can not dissipate the heat well. At this time, products should be timely maintained. At present, the most effective way to deal with the poor heat dissipation of low temp chillers is that deal with it when the heat dissipation of the condenser is poor, the compressor efficiency is low, the running current is increased and the high pressure of air-cooled chillers rises to 24 kg/cm2.
Most poor heat dissipation problems of low temp chillers can be solved by professional equipment maintenance to adjust the operation of low temp chillers. Sometimes when the heat dissipation is poor, the compressor will escape under the protection of high-voltage switch; the compressor will stop running; the high-pressure overload caused by poor heat dissipation will lead to the fault code or fault indication being displayed. In this case, please check whether the cooling tower circulating water is normal, or shut down and restart to normal operation.
Recomendaciones relacionadas
-
Small coup to deal with ice blockage of high and low temperature liquid circulating chillers
818In the operation of high and low temperature liquid circulating chillers, ice blockage is a relatively common fault. Based on the experience of relevant manufacturers, we have specially compiled relevant tips for dealing with ice jams. In the pip...
Ver detalles -
What is the reason for non condensable gas in the condenser of ultra-low temperature cooling water c
1446When the ultra-low temperature cooling water chiller is running, it is necessary to pay attention to the gas state generated by the condenser under a certain temperature and pressure. The existence of these gases affects the operation of the ultra...
Ver detalles -
Hot and cold rapid temperature change test chamber common fault
1042In the high-temperature test of the hot and cold rapid temperature change test chamber, once the temperature change does not reach the test temperature value, in this case, the electrical system can be inspected and the faults can be eliminated on...
Ver detalles -
Prueba del motor del vehículo eléctrico Instrucciones del enfriador del sistema de refrigeración
1303Con el continuo desarrollo de los vehículos de nueva energía, también se está desarrollando el enfriador, el sistema de refrigeración para pruebas de motores eléctricos. El nuevo enfriador para pruebas de motores de vehículos de nueva energía puede ajustar de forma adaptativa el enfriador en función de la dinámica...
Ver detalles