Hybrid car battery test equipment cooling capacity description
Due to insufficient insulation thickness of the hybrid vehicle battery test equipment and pipeline or damage to the insulation layer, the loss of cooling capacity is increased, which affects the cooling effect. In the operation of the hybrid vehicle battery test equipment, once the outer surface of the insulation layer is found to have wet or frosted parts, it means that the thickness of the insulation material is insufficient or has been damp, and the insulation material should be added or replaced in time.
When the equipment is installed, a layer of insulation cotton is placed on the evaporator and the pipeline to prevent loss of cooling capacity. If the hybrid vehicle battery test equipment is slow in cooling, first check whether the thickness of the pipe insulation layer is not enough, or if the insulation layer is damaged, be sure to pack the insulation cotton and ensure that the thickness is sufficient!
Check for air in the equipment cooling system. When installing the hybrid vehicle battery test equipment, whether it is inside the unit, water pump, or pipeline, there can be no air, even if there is only a little air, the cold hybrid vehicle battery test equipment can not operate normally. In addition, there is a film inside the pump, and you must remember to tear it off before installation. Otherwise, the circulating water has no way to circulate or the circulation is very slow, which directly affects the operation of the hybrid vehicle battery test equipment.
Check the moving parts of the refrigeration compressor of the hybrid vehicle battery test equipment for wear, or increase the clearance, resulting in a decrease in the volume of gas. The compressor is the heart of the cooling water machine. If there is a problem with the compressor, the hybrid vehicle battery test equipment will not work. Therefore, the periodic inspection and maintenance of the compressor cannot be ignored.
The poor efficiency of equipment refrigeration compressors is also one of the reasons. In the long-term operation of the hybrid vehicle battery test equipment, the wear of the moving parts, the increase of the matching clearance or the tight sealing will reduce the actual air volume of the compressor and reduce the cooling capacity. Check the refrigeration compressor. If the repair is not good, it should be replaced in time. Air in the system can also cause this to happen. At this time, the exhaust pressure and temperature increase, the power consumption increases, and the cooling capacity decreases.
The cooling of the hybrid vehicle battery test equipment is related to the data of the hybrid vehicle battery test process, so the cooling capacity needs to be better according to the requirements.
Recomendaciones relacionadas
-
Precautions for the use of chemical refrigeration and heating circulation systems
1583In chemical production, the reaction will generate heat, which will cause the heat to be uneven. If it is not discharged in time, it will increase the temperature in the kettle and cause danger. The existing heating system of the reactor is relati...
Ver detalles -
La unidad de refrigeración de etilenglicol irrumpió con fuerza y creó la marca LNEYA en 12 años
2029Performance enhanced positioning When performing the cooling and heating reaction, in many cases, the refrigerant cannot cool the object to be cooled by itself. Therefore, we need a coolant (or refrigerant) to cool the refrigeration system in a re...
Ver detalles -
What reactions are microchannel reactors suitable for?
1697In recent years, micro-chemical technology has developed rapidly, and micro-channel reactors have attracted more and more attention. Microchannel reactors are manufactured with the help of special micromachining technology. They have the advantag...
Ver detalles -
Clean of Ultra-low Temperature Freezer
1364Cleanenvironment of ultra-lowtemperature freezer: Once a monthClean up all ground debris and dust with sanitary ware, reduce dust adsorption in compressor and refrigeration system, affect heat dissipationPrevent dust from adsorbing on circuit boar...
Ver detalles
LNEYA Enfriadoras industriales Fabricante Proveedor










