Principio de mantenimiento del sistema de control de temperatura TCU de líquidos fluorados
The working environment of the fluorinated liquid TCU temperature control system

Fluorinated liquid TCU temperature control system should be placed in a ventilated, dry and clean place;
(2) The distance between the fluorinated liquid TCU temperature control system and the partition is greater than 1m;
(3) The louver holes on both sides of the fluorinated liquid TCU temperature control system must not be obstructed or blocked
- After each use of the fluorinated liquid TCU temperature control system, it is necessary to wipe all kinds of stains, oils and solvents on the surface of the machine with a soft cloth to keep it clean;
3. If the fluorinated liquid TCU temperature control system has been used for more than six months, or the high/low pressure switch often fails, or the cooling capacity is reduced, the condenser needs to be cleaned;
4. If it is not an emergency, it is not allowed to close the fluorinated liquid TCU temperature control system by cutting off the main power supply; if the fluorinated liquid TCU temperature control system is not used for a long time in winter, first close the fluorinated liquid TCU temperature control system, and then close the main power supply. And drain the water in the system;
5. Try not to tighten the interface of the fluorinated liquid TCU temperature control system too tightly, and keep regular activities to avoid being locked;
6. Pay attention to observe the condition of the heat transfer oil in the TCU temperature control system of the fluorinated liquid. If there is any color change, you need to contact the heat transfer oil manufacturer;
7. When maintaining the TCU temperature control system of fluorinated liquid, it is necessary to purchase qualified accessories, and do not replace them at will, so as not to cause a fatal blow to the machine.


Correo electrónico: sales@cnzlj.com
WhatsApp: 086 13912479193
Recomendaciones relacionadas
-
Estructura básica de la enfriadora de agua industrial
1673Estructura básica del enfriador de agua industrial: El enfriador de agua industrial consta de compresor, condensador, evaporador, válvula de expansión y otros accesorios. 1. Compresor: en el sistema de enfriamiento de agua industrial, el compresor es el...
Ver detalles -
10L reactor temperature control equipment
139610L reactor temperature control equipment, also known as oil bath machine, is a device used to accurately control the temperature in the reactor, usually through heat transfer oil (also known as heat transfer fluid) to achieve heating an...
Ver detalles -
Cooling and heating temperature control equipment for liquid distribution system
1349The cooling and heating temperature control equipment of the liquid distribution system is a dynamic temperature control system produced by LNEYA. When we purchase the cooling and heating temperature control system of the liquid distribution s...
Ver detalles -
Microscopio electrónico de barrido Sistema de circulación de agua de refrigeración
1865El microscopio electrónico de barrido (SEM) es un microscopio de alta resolución muy utilizado en la ciencia de materiales, la biología, la nanotecnología y otros campos. El SEM genera una cierta cantidad de calor durante su funcionamiento. Para garantizar un funcionamiento estable y...
Ver detalles
LNEYA Enfriadoras industriales Fabricante Proveedor