Principio de mantenimiento del sistema de control de temperatura TCU de líquidos fluorados
The working environment of the fluorinated liquid TCU temperature control system

Fluorinated liquid TCU temperature control system should be placed in a ventilated, dry and clean place;
(2) The distance between the fluorinated liquid TCU temperature control system and the partition is greater than 1m;
(3) The louver holes on both sides of the fluorinated liquid TCU temperature control system must not be obstructed or blocked
- After each use of the fluorinated liquid TCU temperature control system, it is necessary to wipe all kinds of stains, oils and solvents on the surface of the machine with a soft cloth to keep it clean;
3. If the fluorinated liquid TCU temperature control system has been used for more than six months, or the high/low pressure switch often fails, or the cooling capacity is reduced, the condenser needs to be cleaned;
4. If it is not an emergency, it is not allowed to close the fluorinated liquid TCU temperature control system by cutting off the main power supply; if the fluorinated liquid TCU temperature control system is not used for a long time in winter, first close the fluorinated liquid TCU temperature control system, and then close the main power supply. And drain the water in the system;
5. Try not to tighten the interface of the fluorinated liquid TCU temperature control system too tightly, and keep regular activities to avoid being locked;
6. Pay attention to observe the condition of the heat transfer oil in the TCU temperature control system of the fluorinated liquid. If there is any color change, you need to contact the heat transfer oil manufacturer;
7. When maintaining the TCU temperature control system of fluorinated liquid, it is necessary to purchase qualified accessories, and do not replace them at will, so as not to cause a fatal blow to the machine.


Correo electrónico: sales@cnzlj.com
WhatsApp: 086 13912479193
Recomendaciones relacionadas
-
Unidad de control térmico de reactores y soluciones para productos químicos
1378El control de la temperatura es un proceso en el que se mide o detecta la temperatura de una sustancia o un cambio de temperatura, y se ajusta la transferencia de energía térmica hacia o desde el espacio o la sustancia para alcanzar la temperatura deseada....
Ver detalles -
Selection and installation of the expansion valve for recirculating chillers
985Regarding today's topic, we have thefollowing analysis.The selection of expansion valve plays animportant role in the performance of the recirculating chiller refrigerationsystem. The correct choice of expansion valve will maximize the use of t...
Ver detalles -
Application Note of Low Temperature Refrigerator for Cold Shrink Assembly of Automobile Engine Parts
1172Engine assembly is carried out in a low-temperature environment below minus 30°C in a low-temperature refrigerator. The mainstream automobile engine manufacturers have their own low-temperature assembly workshops. Engines assembled in a low-temper...
Ver detalles -
¿Qué hay que tener en cuenta al comprar un frigorífico de temperatura ultrabaja de -150 °C?
1215-150 ° C ultra-baja temperatura del refrigerador se utiliza en la industria, por lo que lo que los usuarios deben prestar atención después de comprar el equipo del fabricante? A continuación, Wuxi Guanya (LNEYA)-150 ° C ultra-baja temperatura refrigerador fabricantes para siempre...
Ver detalles