Semiconductor production process and testing process temperature control equipment
Use fluid fluorinated liquid for temperature control (minimum -100 degrees)
Gas cold and hot rapid temperature change thermal chuck
Low temperature gas cooler -120 degrees
Direct cooling cooling unit (-150 degrees)
The heating method within 40°C is heated by compressor hot air.
The Chiller ring system adopts a fully enclosed design and a magnetic drive pump.
Chiller100% helium detection, 100% safety inspection, to ensure safety and reliability.
chiller100% after 24 hours of continuous operation copy machine.

Condensador: micro-channel heat exchanger (air-cooled) plate heat exchanger (water-cooled)
Evaporador: Plate heat exchanger Throttling device: Electronic expansion valve Circulation system: The whole system is a fully closed system, low temperature does not absorb moisture in the air, does not volatilize heat transfer medium, low temperature automatically replenishes heat transfer medium into the circulation system.
Shell material: cold-rolled plate spray RAL7035
Inside the pipeline: including stainless steel SUS304, copper, ceramics, broken silicon, silicone sealant, PTFE
Control system: PLC programmable controller
Communication protocol: RS485 interface Modbus RTU protocol
Interfaz Ethernet Protocolo TCP/IP
Operation interface: LNEYA customized 7-inch color touch factory temperature curve display\EXCEL data export
La bomba de frecuencia variable puede ajustar la presión hidráulica de circulación y el caudal
The output pressure and flow rate of circulating fluid can be set on the operation panel. Even under various customer piping conditions, without bypass piping adjustment, the output pressure can be automatically controlled at the set output pressure through the frequency conversion pump. Thereby, the power consumption of a pump can be reduced. Depending on the flow rate, bypass piping may be required
Circulation heating is possible without a heater because it is heated by the exhausted heat
Recomendaciones relacionadas
-
Common Faults of Salt Spray Environmental Chambers
1045The enterprise users are often at a loss when dealing with common faults in the salt spray environmental chamber. For this reason, Wuxi LNEYA, a manufacturer of the salt spray environmental chamber, specially reorganized the related common fault t...
Ver detalles -
Recomendaciones para el uso de equipos de prueba de chips integrados en el proceso de prueba
1034From the perspective of the entire semiconductor industry, semiconductors can be divided into R & D, production, and application stages. At different stages, the role of testing is different. Control of test equipment, including test machines,...
Ver detalles -
Basic maintenance of high and low temperature refrigeration circulating pumps
1385Properly perform the sequence of opening and closing of the high and low temperature refrigeration cycle pump group to ensure normal operation after the host is started. Note that the condenser heats up well, otherwise the high temperature protect...
Ver detalles -
What should I do if there is noise from industrial cooling and heating chillers?
1107The industrial cooling and heating temperature control equipment adopts a PID algorithm temperature control system to accurately adjust the temperature based on the detected temperature and the set temperature value, improving the drawbacks of tr...
Ver detalles