Semiconductor production process and testing process temperature control equipment
Use fluid fluorinated liquid for temperature control (minimum -100 degrees)
Gas cold and hot rapid temperature change thermal chuck
Low temperature gas cooler -120 degrees
Direct cooling cooling unit (-150 degrees)
The heating method within 40°C is heated by compressor hot air.
The Chiller ring system adopts a fully enclosed design and a magnetic drive pump.
Chiller100% helium detection, 100% safety inspection, to ensure safety and reliability.
chiller100% after 24 hours of continuous operation copy machine.

Condensador: micro-channel heat exchanger (air-cooled) plate heat exchanger (water-cooled)
Evaporador: Plate heat exchanger Throttling device: Electronic expansion valve Circulation system: The whole system is a fully closed system, low temperature does not absorb moisture in the air, does not volatilize heat transfer medium, low temperature automatically replenishes heat transfer medium into the circulation system.
Shell material: cold-rolled plate spray RAL7035
Inside the pipeline: including stainless steel SUS304, copper, ceramics, broken silicon, silicone sealant, PTFE
Control system: PLC programmable controller
Communication protocol: RS485 interface Modbus RTU protocol
Interfaz Ethernet Protocolo TCP/IP
Operation interface: LNEYA customized 7-inch color touch factory temperature curve display\EXCEL data export
La bomba de frecuencia variable puede ajustar la presión hidráulica de circulación y el caudal
The output pressure and flow rate of circulating fluid can be set on the operation panel. Even under various customer piping conditions, without bypass piping adjustment, the output pressure can be automatically controlled at the set output pressure through the frequency conversion pump. Thereby, the power consumption of a pump can be reduced. Depending on the flow rate, bypass piping may be required
Circulation heating is possible without a heater because it is heated by the exhausted heat
Recomendaciones relacionadas
-
¿Qué significan los códigos de avería de la enfriadora LNEYA? ¿Cuál es la solución?
2520Q: What is the fault code of the chiller? Answer: E1 means extremely high indoor temperature alarm, E2 means extremely high temperature alarm, E3 means extremely low temperature alarm, E4 means indoor temperature controller failure, E5 means water...
Ver detalles -
Component and component tester for special environments
2543With the continuous development of the semiconductor industry, component component testing has been widely used in components in the fields of industry, scientific research, pharmaceuticals, and chemical industry. At present, there are quite a few...
Ver detalles -
¿Qué procesos de las empresas de materiales ultrafinos requieren enfriadores de agua de refrigeración?
1538Las empresas de materiales ultrafinos suelen necesitar un control preciso de la temperatura durante el proceso de producción para garantizar la calidad del producto y la estabilidad del proceso de producción. Los enfriadores de agua desempeñan un papel clave en múltiples procesos de...
Ver detalles -
Immersion phase change liquid cooling system
1694What is immersion phase change liquid cooling system?
Ver detalles
LNEYA Enfriadoras industriales Fabricante Proveedor