Instructions On Refrigeration Of Low Temperature Chiller Circulating Machine Screw Compressor
Due to different compressors, the performance of refrigerador de baja temperatura circulation machine is also different. Screw compressor is different from the piston compressor, whose structure is more sophisticated. Therefore, if the user needs to choose the refrigerador de baja temperatura circulator, they need to have their own understanding of its refrigeration operation.
When it is on operation, the screw compressor of the refrigerador de baja temperatura circulator sprays lubricating oil into the working chamber, which plays the role of lubrication, cooling, sealing and noise elimination, as well as lubricating oil for main bearing, thrust bearing and shaft seal and the pressure oil that pushes the piston, balances the piston. This oil mixed with high-pressure gas is discharge from the compressor.
Inspiratory filter: the inspiratory filter of circulating machine of refrigerador de baja temperatura is mainly composed of shell and metal filter net, etc. Inspiratory thermometer, pressure gauge and refueling valve are installed on the shell. The refueling valve is the refueling part of the unit, so pay more attention to it.
Oil cooler: the temperature of the lubricating oil separated from the oil of the circulating machine of the low-temperature chiller increases (close to the exhaust temperature) due to the absorption of friction heat and the heat of the gas. If the oil temperature is too high, the viscosity will decrease, which will weaken the sealing effect, increase the internal leakage and reduce the efficiency of the compressor. Therefore, the lubricating oil must be cooled before it can be recycled. Low temperature chiller circulating oil cooler plays the role of cooling oil.
Crude oil filter: in order to protect the normal operation of the circulating oil pump of refrigerador de baja temperatura, the impurities are filtered through the crude oil filter before the lubricating oil enters the oil pump.
When the machine is operating for the first, check the cleanliness of the crude oil filter after the initial operation, and dismantle and inspect the filter screen regularly according to the cleanliness of the system. Gasoline or kerosene can be used to clean the filter and continue using it after blowing it with dry air.
Recomendaciones relacionadas
-
Fallo del compresor del sistema de control de refrigeración causado por la presión del aceite
978If there is no oil pressure in the refrigeration control system, check the oil pump piping system connection for oil leakage or blockage. If the connection is loose, the joint should be tightened. If it is blocked, the oil pipeline should be clear...
Ver detalles -
Product description for ultra-low temperature refrigeration
1034Technical parameters (low temperature cold storage project within 100 cubic meters) of Ultra-Low Temp Cold Storage 1. Medical cold storage temperature range(℃):Low-temperature storage library: -20°C to -50°C Preservation of plasma, biological ma...
Ver detalles -
The difference between air-cooled and water-cooled 15P refrigeration units
1178Because the demand conditions are different, when the selected 15P refrigeration unit is air-cooled and water-cooled, what is the difference? The air-cooled 15P refrigeration unit contains a heat-insulating water tank and water pump in its body, w...
Ver detalles -
What to consider when purchasing an oil-cooled motor power cooling system?
961Purchasing objects is nothing more than based on several types of methods: inquire with people around you, search and consult on the Internet by yourself, so that you can avoid some detours. 1. Parameter requirements: Ordering from the Internet is...
Ver detalles