Descripción de la presión del refrigerador específico de laboratorio
En laboratory-specific chiller is one of the more popular equipments in the mechanical equipment industry. For this reason, the relevant pressure instructions have been specially compiled to help you better understand the laboratory-specific chiller.
The reference value of the test chamber-specific chiller and the pressure resistance of the piping system components refers to the design given pressure related to the mechanical strength of the pipeline components. The nominal pressure is generally expressed by PN. Nominal pressure—the compressive strength of the product at the reference temperature, expressed in PN, unit: MPa, reference temperature: different materials, the reference temperature is also different, for example, the steel reference temperature is 250 ° C, the nominal pressure is 1.0 Mpa, Recorded as: PN 1.0 Mpa.
The working pressure of the special chiller in the laboratory refers to the large pressure specified by the high working temperature of the pipeline conveying medium for the operation safety of the pipeline system. The working pressure is generally expressed by Pt.
The design chiller design pressure of the laboratory refers to the large instantaneous pressure of the water supply pipe system acting on the inner wall of the pipe. The sum of the working pressure and the residual water hammer pressure is generally used. The design pressure is generally expressed by Pe. The test pressure refers to the pressure to be achieved by the pipeline, container or equipment under the pressure resistance and air tightness test. The test pressure is generally expressed by Ps.
The nominal chiller pressure of the laboratory is a nominal pressure artificially specified for the convenience of design, manufacture and use. The unit of this nominal pressure is actually the pressure, and the pressure is the common name of Chinese. The unit is “Pa”. Not “N”. The nominal pressure of a pressure vessel refers to the nominal pressure of the pressure vessel flange. The nominal pressure of the pressure vessel flange is generally divided into seven grades, namely 0.25, 0.60, 1.00, 1.60, 2.50, 4.00, 6.40 MPa.
In general, the pressure can be divided into: test pressure > nominal pressure > design pressure > working pressure, so, everyone understands?
Recomendaciones relacionadas
-
Función de la bomba de agua de la enfriadora de agua industrial
1822La bomba de agua es uno de los componentes auxiliares importantes del sistema de refrigeración del enfriador de agua industrial. Muchas industrias utilizarán el enfriador de agua industrial, pero muchas personas no saben mucho sobre el equipo. Esta vez, lneya r...
Ver detalles -
Instrucciones de seguridad para el uso de aceite térmico circulante de alta temperatura
1647Para que la circuladora de alta temperatura funcione de forma más eficiente, se recomienda prestar atención a la seguridad y a la elección del aceite conductor del calor. A qué debe prestar atención el fabricante del aceite termoconductor de alta temperatura?
Ver detalles -
Temperature control instructions for stainless steel reactors and glass reactors
1836Reactor is a kind of reaction equipment in industrial production. It generally needs to be refrigerated or heated. Whether the temperature is suitable or not directly affects its reaction effect. Therefore, if conditions permit, it is generally e...
Ver detalles -
What should I pay attention to when replacing a water-cooled chiller compressor
1581Once the compressor of the water-cooledchiller fails, the compressor needs to be replaced in time, but the replacementof the compressor is not as simple as imagined.Before the water-cooled chiller compressoris replaced, the reasons for the dama...
Ver detalles
LNEYA Enfriadoras industriales Fabricante Proveedor