Prestaciones y puntos de instalación del frigorífico de temperatura ultrabaja LNEYA
LNEYA Ultra-Low Temp. Congelador es ampliamente utilizado en estaciones de sangre, hospitales, salud y departamentos de prevención de epidemias, institutos de investigación, industria electrónica, medicina química, ingeniería biológica, laboratorio,...
Refrigeration Using single compressor cascade technology, simple structure, low energy consumption, low failure rate; Refrigerant using single compressor cascade technology, simple structure, low energy consumption, low failure rate.Safety Protection; High and low pressure protection and display, Electric leakage protection, Power outage alarm, ambient temperature monitoring, sensor fault alarm,control system UPS power.
In order to achieve the long-term use of low-temperature freezer minus 30 DEG ~-86 DEG and prolong its life, we need to pay attention while using. Today LNEYA will tell something about it and hope them be helpful for you.
1. The indoor temperature should not be too high, it is better to put in the air-conditioned room. Always pay attention to the indoor voltage, keep it stable.
2. Reduce the times of opening the door. Once the sample is not too much. It is suggested that it should be put in batch and classified if the specimen is large.
3. Do not open the door to find things. Take the sample quickly and determinedly.
4. Regular defrosting is also essential.
5. According to the sample storage temperature demand, set the corresponding temperature. When the sample storage temperature needn’t to be-86 degrees.It is not recommended to set the temperature to -86 degrees because this makes the ultra-low temperature refrigerator tired and costly.
Recomendaciones relacionadas
-
Maintenance steps of slope heating and cooling cooling heating thermostat
1515The slope temperature rise and fall cooling heating thermostat is the center to clean dust, garbage, etc. To clean and change inspection, inspection can find problems, find the potential defects of the slope temperature rise and fall high and low...
Ver detalles -
The difference between air-cooled and water-cooled 15P refrigeration units
2003Because the demand conditions are different, when the selected 15P refrigeration unit is air-cooled and water-cooled, what is the difference? The air-cooled 15P refrigeration unit contains a heat-insulating water tank and water pump in its body, w...
Ver detalles -
Causas de la reducción del efecto de transferencia de calor de los refrigeradores verticales de temperatura ultrabaja
1585If the outer frost layer of the vertical ultra-low temperature refrigerator is too thick or excessively dusty, it may cause the external temperature of the equipment to be mostly lower than 0, resulting in low heat transfer efficiency of the evapo...
Ver detalles -
Constant temperature circulation device can help chip to complete reliability test
1563As the country vigorously develops domestic chips, chip manufacturing is entering the fast lane. After the chip is manufactured, there is a very critical link, which is the reliability test, and the constant temperature circulation device can quic...
Ver detalles
LNEYA Enfriadoras industriales Fabricante Proveedor










