Prestaciones y puntos de instalación del frigorífico de temperatura ultrabaja LNEYA
LNEYA Ultra-Low Temp. Congelador es ampliamente utilizado en estaciones de sangre, hospitales, salud y departamentos de prevención de epidemias, institutos de investigación, industria electrónica, medicina química, ingeniería biológica, laboratorio,...
Refrigeration Using single compressor cascade technology, simple structure, low energy consumption, low failure rate; Refrigerant using single compressor cascade technology, simple structure, low energy consumption, low failure rate.Safety Protection; High and low pressure protection and display, Electric leakage protection, Power outage alarm, ambient temperature monitoring, sensor fault alarm,control system UPS power.
In order to achieve the long-term use of low-temperature freezer minus 30 DEG ~-86 DEG and prolong its life, we need to pay attention while using. Today LNEYA will tell something about it and hope them be helpful for you.
1. The indoor temperature should not be too high, it is better to put in the air-conditioned room. Always pay attention to the indoor voltage, keep it stable.
2. Reduce the times of opening the door. Once the sample is not too much. It is suggested that it should be put in batch and classified if the specimen is large.
3. Do not open the door to find things. Take the sample quickly and determinedly.
4. Regular defrosting is also essential.
5. According to the sample storage temperature demand, set the corresponding temperature. When the sample storage temperature needn’t to be-86 degrees.It is not recommended to set the temperature to -86 degrees because this makes the ultra-low temperature refrigerator tired and costly.

Recomendaciones relacionadas
-
The benefits of choosing a cryostat
1348The temperature of the effluent of the cryogenic refrigerator is very low, so the carrier medium can not be used for water (the water will freeze when it reaches 0 ° C). At this time, it is necessary to use a brine solution or a glycol solution, a...
Ver detalles -
Ultra Low Temp Chiller Compressor Common Protection Instructions
865The ultra low temp chiller compressor is a relatively important part of all its components. In the course of operation, certain protective devices are needed to help the compressor operate safely. What specific protection? Let's take a look! The m...
Ver detalles -
Industria e introducción del refrigerador de baja temperatura
949En el refino de petróleo, la industria petroquímica, la síntesis orgánica, los productos químicos y otras producciones industriales, la tecnología de refrigeración debe aplicarse para controlar la temperatura de reacción durante procesos como la licuefacción, la condensación, ...
Ver detalles -
Cómo prolongar la vida útil del sistema de refrigeración por glicol?
991Para prolongar la vida útil de su enfriadora de glicol en aplicaciones industriales, preste atención a los siguientes puntos: 1. No utilice anticongelante para automóviles o anticongelante no cualificado. Debido a que este ...
Ver detalles