LNEYA walk-in test chamber Characteristics:
Wide temperature control range can meet the user’s various needs.
Unique balanced temperature control method, a stable and balanced heating capacity can be used for high precision and high stable temperature control.
The temperature displayed by touch screen, easy to read, precise and convenient.
The temperature error can be adjusted to meet your more accurate test conditions.
Automatically selecting and running the cooling circuit with the setting of temperature, with simple operation.
The door is equipped with a large observation window, which can observe the test status of the sample.
With high temperature starting function, the chamber can be turned on when the temperature in rises to 100 degrees. It is convenient for continuous round-trip test between high temperature and low temperature.
With self-diagnosis function, overload protection , high pressure switch, overload relay, thermal protection device, etc.
With multi-wing fan used to circulate and avoid any dead Angle, so that the temperature can be distributed evenly in the test area.
The air circuit is designed with the wind return wind, the wind pressure and wind speed are in accordance with the test standard, and can make the opening instant temperature regain fast.
Heating, cooling, and completely independent system can improve efficiency, reduce test cost, increase life span and reduce failure rate.
The water tank is placed on the side of the unit with water shortage and automatic protection.
The humidifying system is separated from the control circuit board, which can avoid the failure of water leakage in the humidified pipeline to improve the safety.
The system of waterway system is opened by door to facilitate maintenance and repair.
In the refrigeration system, the condensation adopts air – cooling mode or water – cooling mode.
LNEYA’s walk-in test chamber has 15 volumes that can be customized.
Recomendaciones relacionadas
-
La razón por la que el termostato de refrigeración Chiller de repente no arranca
1592Si se produce alguna situación inesperada durante el uso del termostato de refrigeración Chiller, es importante identificar rápidamente las razones específicas antes de resolverlas, con el fin de abordar eficazmente diversas cuestiones. Por ejemplo, ¿cuál es el re...
Ver detalles -
How to clean the battery cooling system of new energy vehicles?
1407The battery cooling system of the new energy model first unscrews the three screws on the upper part of the wet curtain, holds the louvers on the upper part of the wet curtain, gently pulls the wet curtain outward and then lifts it up slightly to ...
Ver detalles -
¿Cuáles son las aplicaciones de la unidad de refrigeración criogénica de extracción supercrítica de CO2?
1639Con el continuo desarrollo de la tecnología de extracción supercrítica de co2, los dispositivos de refrigeración criogénica de extracción supercrítica de co2 han atraído la atención de muchas industrias debido a sus propias características, y se han utilizado ampliamente en...
Ver detalles -
¿Cómo comprobar los componentes del control de temperatura del chip con un multímetro?
1867El dispositivo de control de temperatura de chips se utiliza en componentes como chips, semiconductores y circuitos integrados. ¿Cómo se utiliza un multímetro para estos componentes comunes? Transformadores, bobinas de desviación, inductores de compensación, etc. de c...
Ver detalles
LNEYA Enfriadoras industriales Fabricante Proveedor