Precautions for installation of special chiller for new energy testing
The installation of the special chiller for new energy testing is an important link before operation. The quality of the installation is directly related to the operation and operation status of the special chiller for new energy testing. So, what should be paid attention to in the installation of the special chiller for new energy testing?
If the special chiller for new energy test adopts semi-hermetic or fully-hermetic compressor, an oil separator should be installed, and an appropriate amount of oil should be added to the installed oil separator. When the evaporation temperature is lower than -15 degrees, a gas-liquid should be installed. Separator and add appropriate amount of refrigeration oil. Secondly, the compressor base should be installed with a shock-absorbing rubber seat, and the installation of the special chiller for new energy testing should leave a maintenance space to facilitate the observation of the adjustment of instruments and valves.
The high pressure gauge of the special chiller for new energy testing should be installed at the tee of the liquid storage and filling valve. The overall layout of the special chiller for new energy testing is reasonable and the color is the same. The installation structure of each type of unit should be consistent.
When debugging the special chiller for new energy test, it is necessary to pay attention to measuring the power supply voltage, measuring the resistance value of the three windings of the compressor and the insulation of the motor, checking the opening and closing of each valve of the refrigeration system, and pouring the refrigerant into the storage liquid to the standard charge after evacuation. 70%-80% of the filling volume, and then run the compressor, add air from low pressure to enough volume.
After the special chiller for new energy test is turned on, first listen to whether the sound of the compressor is normal, check whether the condenser and air cooler are running normally, and whether the three-phase current of the compressor is stable. After the special chiller for new energy test cools down smoothly, check the exhaust pressure, suction pressure, exhaust temperature, suction temperature, motor temperature, crankcase temperature, and expansion valve temperature in the refrigeration system, and observe the frosting of the evaporator and expansion valve. , observe the oil level and color change of the oil glass. Check whether the sound of the special chiller for new energy testing is abnormal.
Another point is that the special chiller for new energy testing needs to pay more attention to its maintenance knowledge and carry out a lot of related maintenance work.
Recomendaciones relacionadas
-
Varios aspectos de atención del ultracongelador
1795El rendimiento del congelador de ultra baja temperatura se reducirá naturalmente debido a la aplicación de largo período en todos los campos. Por lo tanto, Guanya Refrigeration Technology Co., Ltd, líder en fabricantes de congeladores de temperatura ultra baja tiene que recordar a todos los usuarios...
Ver detalles -
Application Of Jacketed Reactor Cooling And Heating System In Chemical Reactions
1573In the chemical industry, jacketed reactor cooling and heating devices are widely used in various chemical reactions. Application of jacketed reactor cooling and heating devices in various chemical reactions: Polymerization is a c...
Ver detalles -
La importancia del control de la temperatura para procesar plantas de cannabis
1494La legalización del cáñamo industrial en Europa, América y otros países ha aumentado la demanda de equipos para el procesamiento del cáñamo. Con el tiempo, el cannabis se presenta en forma de extracto de CBD. Con el fin de convertir la planta en un concentrado para medic...
Ver detalles -
Cámara de pruebas de ciclos de temperatura específicos para baterías Puntas de enfriador
1647Con el rápido desarrollo de la economía, la industria automovilística de nuevas energías también ha alcanzado un rápido desarrollo, y los requisitos de la industria de baterías también son cada vez mayores. Para adaptarse a las industrias relacionadas, LNEYA ha...
Ver detalles