2. Air-cooled module internal filter, in order to better filter impurities in the water system, the protective plate heat exchanger is generally more than 40 meshes, that is to say, its filter is more dense and finer than other brands. The advantage of this method is that it can filter impurities better, and the disadvantage is that the number of cleaning increases. But compared with the air-cooled module machine, the closed circulating water system can better ensure the cleaning of the water system in the future as long as the filters are cleaned in time during the initial operation.
3. Inspection and cleaning of end filters. Water filters are installed in both air conditioning boxes and fan coil units at the end. These water filters need to be checked and cleaned, which is also an indirect reason affecting the water system and can improve the cooling effect of the end.
4. We can’t start it forcibly. We are used to turning it on when something goes wrong. In fact, it is a serious operation error for water chiller, especially the frequent power failure and reset of the chiller, which results in the failure of protection, just like a car with frequent high water temperature failure and failure to deal with it, which eventually leads to the breakdown.
Our company provides small water chiller units, welcome to buy!
Recomendaciones relacionadas
-
Selection method of 0℃~5℃ freezing liquid for industrial ultra-low temperature chiller
927As the requirements for process production become higher and higher, industrial ultra-low temperature chillers are required to provide cryogenic liquid below 5 degrees or even more than minus 100 degrees in some chemical process synthesis, reactor...
Ver detalles -
How to solve the problem of insufficient cooling capacity of semiconductor cooling cycle system?
1277The semiconductor cooling cycle system is a device for cooling the semiconductor heating part. LushiA reminds that if the cooling capacity is insufficient during the operation, it is necessary to check in time to see if something has gone wrong. W...
Ver detalles -
Descripción de las características de la cámara de pruebas walk-in LNEYA
839Wide temperature control range can meet the user's various needs.Unique balanced temperature control method, a stable and balanced heating capacity can be used for high precision and high stable temperature control.The temperature displayed by tou...
Ver detalles -
Mantenimiento de los 10 mejores congeladores industriales
1183Cuando elegimos y compramos congeladores industriales de las 10 mejores marcas, además de algunas necesidades necesarias, también debemos prestar atención al uso y mantenimiento del congelador industrial, debemos seleccionar congeladores industriales con larga vida útil, alta ...
Ver detalles