instrucciones de selección del refrigerador del reactor de 500 litros
The 500 liter reactor chiller is used more in the pharmaceutical industry. Therefore, the user needs to select a regular manufacturer when selecting, and at the same time, understand the features and configuration.
For the selection of 500 liter reactor chiller, comprehensive technical and economic comparison should be made according to working conditions, cooling capacity, local power source, water source, heat source, gas source and other factors through investment, operation cost, energy consumption and environmental protection. Then determine the budget.
In areas with abundant power supply, the 500-liter reactor chiller unit with limited power should be selected. Generally, in the case of Q0>1163kw, the centrifugal 500 liter reactor chiller group is generally used; when Q0=582~1163kw, it is generally adopted. The screw type 500 liter reactor chiller group or the centrifugal type 500 liter reactor chiller group; when Q0 < 582 kW, the piston type 500 liter reactor chiller group is generally used.
Generally, the energy efficiency ratio of an electric-powered refrigerator is higher than that of an absorption-type 500-liter reactor cooler group. The order of energy consumption per unit cooling capacity is generally: centrifugal, screw, piston, and absorption ( Direct combustion type, steam type, hot water type). For places with residual heat or waste heat utilization and places where electricity is lacking, the absorption type 500 liter reactor cooler group should be preferred.
Wuxi Guanya (LNEYA) 500 liter reactor chiller adopts fully enclosed circulation pipeline, compact structure, single-machine self-cascading refrigeration technology, and brand accessory configuration to achieve rapid cooling.
Recomendaciones relacionadas
-
Method for connecting reaction kettle and electric control cabinet of reaction equipment
1646The supporting equipment of the reaction kettle is the temperature control product provided by our company for the majority of users for the users. When the user selects the equipment for the reaction kettle, it is necessary to understand the conn...
Ver detalles -
Selection of heat transfer oil for the refrigeration and heating system of the reactor
1832In the chemical industry, the reactor is a commonly used container, and temperature control is the main quantity to be controlled. The heating and refrigeration cycle equipment of the reactor is an important factor to ensure product quality. The r...
Ver detalles -
El sistema de refrigeración y calefacción añade una solución de temperatura para la industria farmacéutica y química
1558LNEYA es un fabricante profesional de diversos instrumentos de control de temperatura desde hace más de diez años. Participa en los sectores farmacéutico, químico, de investigación científica, industrial, de nuevas energías, de chips y otros. La investigación y el desarro...
Ver detalles -
Where do you need explosion-proof water chillers?
1364Explosion-proof refrigeration unit water chillers (explosion-proof chillers) are mainly used in environments with explosion risks to ensure the safety and reliability of the cooling process. This type of equipment is specially designed to ...
Ver detalles
LNEYA Enfriadoras industriales Fabricante Proveedor