Aumento de la temperatura del biorreactor y equipo de control de la temperatura
A bioreactor is a reaction system in which a naturally occurring microorganism or a microorganism having a special degrading ability is inoculated into a liquid phase or a solid phase. The two reactors currently studied the most are “elevator type reactors” and “soil mud reactors”. The elevator type reactor provides the proper nutrients, carbon sources and oxygen through the flow of the aqueous phase to achieve the purpose of degrading pollutants in the soil. Compared to solid phase systems, bioreactors are capable of effectively degrading contaminants in less time.
Bioreactors sound strange, but the basic principles are quite simple. The stomach is a complex bioreactor that processes food inside the body. The food is digested by various enzymes in the stomach and becomes a nutrient that we can absorb. Bioengineering bioreactors are functions that mimic the function of living organisms in vitro and are designed to produce or test various chemical reaction devices. In other words, a bioreactor is a device system that uses a biological function of an enzyme or an organism (such as a microorganism) to perform a biochemical reaction in vitro, and is a biological function simulator such as a fermentor, an immobilized enzyme, or an immobilized cell. Reactor, etc. Then the problem of how to cool the bioreactor is generated.
Wuxi Guanya LNEYA refrigeration heating temperature control system adopts fully enclosed pipeline design, adopts high efficiency plate heat exchanger, and is applied to the temperature rise and temperature control of glass reactor, metal reaction kettle and bioreactor, especially suitable for reaction process. There is a need for heat and heat release process control.
Temperature process control principle (control reactor material temperature)
TCU temperature control unit schematic
1. The method of changing the control set value can respond to the system lag in the process as soon as possible, and obtain the minimum system overshoot. The control consists of two sets of PIDs (each set of PIDs are variable) control loops. These two sets of control loops are called: the primary loop and the slave loop, and the control loop of the master loop is used as the setpoint of the slave loop. The system adopts feedforward PV, and the output of the PID operation result of the main control loop is combined with the feedforward PV signal as the set value of the slave control loop, so that the temperature change gradient is controlled to ensure the temperature control accuracy of the system. (General anti-lag cascade control)
2. A specially designed lag predictor (no model self-built tree algorithm) generates a dynamic signal yc(t) instead of the process variable y(t) as a feedback signal. An e(t) signal is generated to the controller to cause the controller to predict that there is no large hysteresis in the control, so that the controller can always generate a suitable control signal. That is to say, even if there is a large hysteresis, the dynamic signal yc(t) can keep the feedback loop working normally. While the general PID is used to control the process with significant time lag, the controller output is not suitable due to the lag time. The feedback signal keeps growing, causing the system to overshoot and even out of control.
3. Through three-point sampling (material temperature point, temperature control system outlet temperature, temperature control system inlet temperature), through our company’s own model-free self-built tree algorithm and general anti-lag cascade algorithm.
Recomendaciones relacionadas
-
Description of driver chip power supply in chip test temperature control system
1390The chip test temperature control system is mainly for the cold heat source test equipment for various drive chips. Before the operation of the Wuxi Guanya chip test temperature control system, the user needs to know the power of the drive chip. I...
Ver detalles -
Condiciones ambientales para la instalación de enfriadoras por aire
1675Como todos sabemos, la instalación de la mayoría de las máquinas debe adaptarse al entorno y las condiciones. Por supuesto, nuestras enfriadoras industriales por aire no son una excepción. Si el enfriador refrigerado por aire no se instala por primera vez, traerá un montón de...
Ver detalles -
Proceso de congelación del eje rotatorio en el montaje de motores de automóviles de nueva energía
1980A medida que el mercado de vehículos de nueva energía se ha ido expandiendo gradualmente, la industria de fabricación de motores de nueva energía también ha crecido. Por lo tanto, para el fabricante de motores, el rotor en el proceso de núcleo durante el proceso de montaje del motor es particularmente importante....
Ver detalles -
How to use industrial water chiller to reduce environmental pollution
1297With the continuous development of chemicaland pharmaceutical industries, environmental pollution is put on the agendaearlier. As an manufacturer of which is the industrial water chiller, I can saythat except for corresponding to the environmen...
Ver detalles
LNEYA Enfriadoras industriales Fabricante Proveedor











