TCU temperature control model selection and technical parameter description
TCU temperature control is also a two-cycle unit single-fluid temperature control system. When selecting the model, it is very important for the whole temperature control reaction. Only the appropriate reaction system is used to exotherm and absorb the whole reaction process. The heat responds to the entire control, so the choice of model is very important.
TCU temperature control model: SR-10
Model SR-10 with operating temperature range of -120~200°C, suitable reaction vessel is 50L-250L, circulating pump flow pressure is controlled at 3m3/h1.5bar, circulating pump can not be adjusted, auxiliary heating power is 10KW, pre- The interface of the heat exchange module is DN25, and electric power, steam, hot oil, hot water, cooling water, chilled water and ultra-low temperature medium can be used as primary energy.
TCU temperature control model: SR-20
Model SR-20 with operating temperature range of -120~200°C, suitable reaction vessel is 100L-500L, circulating pump flow pressure is controlled at 2.4~6.6m3/h1.5bar, circulating pump control can be adjusted by frequency or fixed speed. The auxiliary heating power is 20KW, and the interface of the preheating heat exchange module is DN32.
TCU temperature control model: SR-38
Model SR-38 with operating temperature range of -120~200°C, suitable reaction vessel is 300L-1000L, circulating pump flow pressure is controlled at 5~12m3/h2.5bar, circulating pump control can be adjusted by frequency or constant speed, auxiliary The heating power is 38KW, and the interface of the preheating heat exchange module is DN40.
TCU temperature control model: SR-60
Model SR-60 with operating temperature range of -120~200°C, suitable reaction vessel is 500L-2000L, circulating pump flow pressure is controlled at 11~25m3/h2.5bar, circulating pump control can be adjusted by frequency or constant speed, auxiliary The heating power is 60KW, and the interface of the preheating heat exchange module is DN65.
TCU temperature control model: SR-95
Model SR-95 with operating temperature range of -120~200°C, suitable reaction vessel is 1000L-5000L, circulating pump flow pressure is controlled at 20~50m3/h2.5bar, circulating pump control can be adjusted by frequency or fixed speed, auxiliary The heating power is 95KW, and the interface of the preheating heat exchange module is DN80.

In addition, the energy conversion of TCU temperature control is carried out by heat exchanger and electric heating. In the temperature control mode selection, the material temperature control and jacket temperature control can be freely selected, and the material temperature control accuracy is ±1 °C. Inch / inch color touch screen. The temperature control of the whole TCU is a fully enclosed system. There is no oil mist at high temperature and no moisture in the air at low temperature. The TCU temperature control system does not increase the fluid pressure due to high temperature during operation, and automatically supplements the heat transfer medium at low temperature.
Recomendaciones relacionadas
-
The role of temperature control system TCU in chemical and pharmaceutical reactor
1286The temperature control of the reaction kettle in drug research and development and chemical experiments, as well as the temperature control in small-scale experimental production and industrial production processes, require highly dynamic tempera...
Ver detalles -
High-quality professional equipment helps the laboratory to produce endless results
1754In recent years, China's economy has continued to grow. Under the development opportunity of professional high and low temperature integrated machines, laboratory scientific and technological achievements are also in sustainable development. LNEYA...
Ver detalles -
Battery test water cooler common knowledge description
1223Battery test Water-cooled air intake If there is no superheat, there may be a return air with liquid, and even cause a wet stroke liquid shock to damage the compressor. In order to avoid this phenomenon, a certain degree of suction superheat is re...
Ver detalles -
Descripción del compresor del dispositivo de prueba de calor húmedo a alta y baja temperatura
1244Different types of compressors for high and low temperature damp heat test devices often have an impact on price. When choosing, we should choose low-energy refrigeration compressors as much as possible. Now China is paying more and more attention...
Ver detalles