What should be paid attention to when placing the thermostat system?
There are certain differences in the size and performance of the high and low temperature thermostat systems produced by different manufacturers. The user needs to pay attention to how it is placed when placing it after purchase, otherwise it will be detrimental to the operation of the high and low temperature thermostat system.
The location where the high and low temperature thermostat system is installed should consider the heat dissipation efficiency and whether it is easy to check and maintain. The floor where the equipment is placed must be flat and have sufficient strength (3.4N/m2 or higher). Choose a place where dust and vibration are less affected s position.
The high and low temperature thermostat system should be installed in a dry room, and there should be a power supply and a sewer nearby. The equipment should be installed in a place with little dust, and the wind condition will cause the refrigerant (fluorohydrocarbon) to leak from the equipment. There will be no hypoxia.
Good ventilation should be maintained around the installation of the high and low temperature thermostat system. During operation, the equipment will radiate heat. If it is an air-cooled thermal shock, it will directly emit heat through the condensing wind. When the room is small and poorly ventilated, the indoor temperature will rise rapidly, causing the machine to stop running and alarm . Secondly, the installation should be far away from flammable or explosive materials or other materials that may generate high heat.
When placing it, please be careful not to let sunlight directly shine on the equipment. When the equipment is used beyond this range, the safety device will start or the equipment will stop running. In order to obtain stable performance of the high and low temperature thermostat system, the installation room should be air-conditioned to keep the indoor temperature between 10°C and 30°C.
The atmospheric environment of the installation site of the high and low temperature thermostat system is consistent with the general indoor air-conditioned atmospheric environment. If there are organic solvents, plasticizers, acids, alkalis or other chemicals in the air, the parts or coatings of the equipment will be corroded and damaged.
The above content is the precautions when placing the high and low temperature thermostat system, which requires the operator to take it seriously and read the instruction manual in detail.
Recomendaciones relacionadas
-
Discussion on maintenance of high and low temperature integrated cycle machine
1785LNEYA high and low temperature integrated cycle machine is a refrigeration heating equipment produced by the use of refrigeration heating dynamic temperature control technology. The temperature range is from -120 °C to 350 °C. It has superior perf...
Ver detalles -
Cómo funciona el sistema de enfriadoras de agua industriales?
1967Cuando se utiliza maquinaria industrial, puede ser necesario un sistema de refrigeración para evitar que la máquina se sobrecaliente. Los equipos de refrigeración pueden mantener eficazmente los materiales en el rango óptimo de temperatura, pero ¿cómo funciona el refrigerador? Entender el funcionamiento...
Ver detalles -
Chiller for heat deflection temperature instrument
1643Temperature range: The temperature of the cooling water is usually required to be between 6 ℃ and 18 ℃.Temperature difference requirement: The temperature difference of the cooling water should be controlled wit...
Ver detalles -
Instrucciones de limpieza del aceite térmico en el sistema de circulación secundaria del aceite térmico
1712El sistema de circulación secundaria de aceite térmico utiliza el aceite térmico como medio para controlar la temperatura de refrigeración y calefacción. A continuación, cuando el usuario limpia el aceite térmico en el sistema de circulación secundari...
Ver detalles
LNEYA Enfriadoras industriales Fabricante Proveedor