Ultra Low Temp Chiller Compressor Common Protection Instructions
En ultra low temp chiller compressor is a relatively important part of all its components. In the course of operation, certain protective devices are needed to help the compressor operate safely. What specific protection? Let’s take a look!
The most common protection for ultra low temp chiller compressors is the suction and exhaust pressure protection. Basically, each ultra low temp chiller will be equipped with this protection device. The main function of the ultra-low temperature chiller compressor is to take charge of the intake and exhaust, and the working chamber is used to perform compression between the intake and exhaust. The pressure molding of the ultra low temp chiller is installed to prevent the intake and exhaust pressure from being caused. If there is a problem with the suction and exhaust pressure, subsequent operations will not function properly, and ultra low temp chillers will not cool properly.
Then there is the oil pressure difference protection device for the ultra low temp chiller compressor. Some manufacturers install the oil separator when producing the ultra low temp chiller. Therefore, the ultra low temp chiller compressor must have a hydraulic pressure difference protection device. Why? Because the frozen lubricating oil is critical to the compressor of the ultra low temp chiller, and if the frozen lubricating oil is not normal, the compressor will also be abnormal.
In addition to the above-mentioned common faults, other common exhaust temperature protection, which, has the same effect asthe suction and exhaust pressure protection of the ultra low temp chiller compressor, because the inhalation temperature is often not problematic, problems lie in the exhaust temperature. Most of the time, if the exhaust pressure is high, the exhaust temperature will be high. In addition to installing the exhaust pressure protection device, installing the compressor exhaust temperature protection device is actually a two-pronged method. After all, the compressor is more important core components, and there must be no problems.
Of course, the protection configuration of each ultra low temp chiller is also different. Wuxi Guanya also specially sets safety protection devices to protect everyone’s environment.
Recomendaciones relacionadas
-
Chemical cooling and heating system – dynamic temperature control system manufacturer
834In the pharmaceutical and chemical industries, cooling and heating system are widely used. As the developing of internet, many enterprises compete fiercely. The following will introduce the benefits of the LNEYA chemical cooling and heating system...
Ver detalles -
Instrucciones para el condensador de congelación LNEYA 5hp
11115hp congelador es uno de los equipos más exigentes en la industria de procesamiento en frío. Wuxi Guanya (LNEYA) es uno de los fabricantes relacionados, recordando a los usuarios que la hora de elegir un condensador congelador 5hp, tenemos que prestar atención a la us...
Ver detalles -
Enfriadora de agua serie KRY para pruebas de calidad de vehículos de nueva energía
1019The new energy vehicle powertrain test bench can be directly connected to the power output end of the electric drive assembly through the half-shaft. The front end is equipped with high-precision torque sensor and speed sensor to provide high-pre...
Ver detalles -
Basic structure manual of industrial chiller
1208Industrial chillers are composed of compressors, condensers, evaporators, expansion valves and other accessories. 1. Compressor: In the industrial chiller system, the compressor is the power to ensure refrigeration. The compressor is used to incre...
Ver detalles