Automotive antifreeze test test temperature control system
When it comes to car antifreeze, we all know that its main function is to prevent the coolant from freezing and cracking the radiator and freezing the engine cylinder block or cover when we stop in the cold winter. Make the cooling system in the best working condition and ensure the normal working temperature of the engine.
The freezing point of water is 0°C, and ordinary antifreeze can reach -40°C, while high-quality antifreeze should be able to reach about -60°C, and the antifreeze has a high boiling point. The boiling point of water is 100 °C, and the boiling point of high-quality antifreeze coolant is usually 110 °C above zero, so it is more difficult to boil antifreeze coolant than water in summer.
Antifreeze detection items: freezing point detection, antifreeze detection, low temperature stability, thermal stability, etc. In these tests, temperature control is left off. When the testing organization carries out these testing items, it is necessary to ensure the constant temperature environment, cooling and heating temperature difference, time and so on during the testing process.
LNEYA automotive antifreeze cooling, heating, temperature control and flow system KRY series equipment is the temperature and flow control equipment required by this type of organization. The temperature range is minus 40 degrees to 100 degrees. The temperature changes during the test are visualized, and the data storage and report analysis can be exported for the convenience of the technicians of the testing organization.
The temperature test mentioned here is the high temperature endurance test and the low temperature endurance test. The low temperature endurance test mainly tests the cold start performance, the charging and discharging ability, the charging and discharging ability of the battery pack at high temperature, the cooling function of the battery pack and the overheat protection strategy.
Our LNEYA KRY series cooling, heating, temperature and flow control systems are the best choice for testing institutions, saving costs and increasing the efficiency and accuracy of testing.
Recomendaciones relacionadas
-
The importance of constant temperature equipment in oil bath heating systems
1586The constant temperature equipment of the oil bath heating system is used for dynamic temperature control of fluid cooling and heating with heat conducting medium, which is applied to high-precision industries such as pharmaceuticals, chemicals a...
Ver detalles -
Cómo utilizar el termostato del reactor?.
1618The reactor thermostat is generally heated by a resistance wire, cooled by a compressor, and is supplemented with a PID controller to maintain a relatively standard temperature, so as to achieve the purpose of the experiment. The shell is made of ...
Ver detalles -
High temperature test equipment related troubleshooting
1735The high temperature test equipment is mostly caused by water shortage in the water circulation. This way, the purified water is replenished to the water tank until the water level meter on the lower right side of the water tank reaches about 80% ...
Ver detalles -
The main purpose of the reactor heating and cooling system
1865The reaction kettle heating and cooling system is suitable for high-purity metals, rare substance purification, laboratory environment simulation, magnetron sputtering, vacuum coating and other industries. The large-scale cryogenic pump unit can p...