Vocs condensing separation equipment expansion valve maintenance instructions
Once the expansion valve of the vocs condensing and separating device fails, if the solution is not solved in time, the entire vocs condensing and separating device may be unavailable. Therefore, the failure of the expansion valve of the vocs condensing separation device needs to be solved in time, and attention is paid to maintenance.
Before servicing the expansion valve, it is necessary to observe whether the expansion valve is normally closed. The ability to open and close the expansion valve in time means that the vocs condensing separation device is used normally, and can quickly reduce the ambient temperature in a short time. Conversely, if there is a fault in the expansion valve, then the pressure inside the vocs condensing separation device appears to be high or low. If the vocs condensing separation device expansion valve failure is not handled in time, the operational safety of the vocs condensing separation device will be affected, even jeopardized. To the company’s normal use of vocs condensation separation equipment.
In order to protect the vocs condensing separation equipment evaporator and expansion valve, in order to avoid the impact of the vocs condensing separation equipment operating power is affected, the company needs regular maintenance of the expansion valve and evaporator. It can eliminate the common faults of vocs condensation separation equipment in time, and clean up the surface and internal components of vocs condensation separation equipment, which can prolong the service life of vocs condensation separation equipment and create conditions for reducing the cost of vocs condensation separation equipment.
The vocs condensing separation equipment expansion valve blockage is a frequent occurrence, the main cause of dirty plugging is the presence of impurities in the system, such as welding slag, copper filings, iron filings, fibers and so on. The reason for ice blockage is that the system contains too much moisture (moisture). For light ice blockage, hot towel can be applied to the ice block. If the ice blockage is serious and has affected the normal operation of the system, it should be replaced. Filter the dryer, re-discharge the water in the system piping, evacuate, and refill the refrigerant.
It should be noted that the expansion valve of the vocs condensing separation equipment can be solved by contacting the vocs condensing separation equipment manufacturer if it cannot be solved during installation and maintenance.

Recomendaciones relacionadas
-
Prestaciones y puntos de instalación del frigorífico de temperatura ultrabaja LNEYA
895LNEYA Ultra-Low Temp. Congelador es ampliamente utilizado en estaciones de sangre, hospitales, salud y departamentos de prevención de epidemias, institutos de investigación, industria electrónica, medicina química, ingeniería biológica, laboratorio,...
Ver detalles -
Compressor key protection of reactor temperature control system
1249In the operation of the reactor temperature control system, the compressor is the core part, and its performance is more important. Therefore, it is necessary to protect the compressor. Under normal working conditions, the compressor of the temper...
Ver detalles -
Mantenimiento de los 10 mejores congeladores industriales
1186Cuando elegimos y compramos congeladores industriales de las 10 mejores marcas, además de algunas necesidades necesarias, también debemos prestar atención al uso y mantenimiento del congelador industrial, debemos seleccionar congeladores industriales con larga vida útil, alta ...
Ver detalles -
LNEYA data center liquid cooling solution Liquid Cooled CDU Distribution Unit
1338LNEYA data center liquid cooling chiller CDU
Ver detalles