Solución a los fallos de alta y baja presión en enfriadoras por agua
The method to eliminate the shortcomings of high and low pressure of water-cooled chiller has always been a key point and difficulty in the industry, so it is very important to master the solutions to the shortcomings of high and low pressure of water-cooled chiller. The reason can be preliminarily identified as poor water quality, and corresponding impurities (leaves, weeds, etc.) enter the water distribution hole, which affects the heat dissipation of the cooling water tower. Next, I will introduce the reasons and solutions for the high and low pressure disadvantages of a water-cooled chiller.
Causes and solutions of high and low pressure disadvantages of water-cooled chiller:
In the application of water-cooled chiller, we often encounter high and low pressure alarm of chiller! In terms of high pressure, it is generally poor heat dissipation, which will lead to poor cooling effect of the chiller. For a long time, high pressure will also lead to high current and burn out the compressor. Generally, there is no cold coal or cold coal leakage in the low pressure alarm. The compressor will also be damaged if it works at low pressure for a long time.
Generally, water-cooled chillers have high and low pressure gauges, which are divided into high pressure and low pressure. In addition, industrial chillers are roughly divided into air-cooled chillers and water-cooled chillers: at present, the surface plate of industrial chillers on the market is divided into computer board and manual control board. High pressure and low pressure of computer board are well separated, but generally, the high and low pressure alarm lights of manual control board chillers are together, so it is not so easy to distinguish.
Therefore, you should first know whether the chiller you are using is an air-cooled chiller or a water-cooled chiller, whether it is a computer board or a manual control board, whether it is a high-pressure alarm or a low-pressure alarm. For the high-pressure alarm of the air-cooled chiller, you need to clean the cooling network, and for the low-pressure alarm, you need to check whether the cold coal leaks or the pressure gauge has no pressure, The high pressure alarm of water-cooled chiller requires cleaning the condenser. Low pressure alarm also depends on whether the pressure gauge has no pressure, so it is necessary to check the leakage, make up the deficiency and add cold coal.
Recomendaciones relacionadas
-
Las principales áreas de aplicación de las enfriadoras por aire
1797En el mercado nacional e internacional de enfriadores de agua industriales, nuestros equipos más comunes de enfriadores de agua industriales pueden dividirse a grandes rasgos en dos tipos diferentes, un tipo es el enfriador de aire industrial, el otro tipo es el enfriador de agua industrial....
Ver detalles -
Model and size selection of cooling and heating circulator (pilot plant temperature control system)
1714The cooling and heating circulator adopts mechanical refrigeration, the low-temperature heating tube heats the high temperature, and the canned pump is used as the circulating pump. The liquid circulation of the whole system is closed and consists...
Ver detalles -
¿Cuál es la temperatura del circulador de refrigeración criogénica?
1685The LNEYA cryogenic cooling circulator has a cooling temperature range from -125 degrees to -20 degrees. It adopts a computer cascade temperature controller and a PT100 temperature sensor, and the temperature control accuracy can reach ±0.1 degree...
Ver detalles -
Analysis of the characteristics of LNEYA precision chillers
1736Now, in many industrial productions, industrial chillers are needed to achieve the purpose of refrigeration in production operations. This shows that chillers play a very important role in various industrial production. The precision chiller uses ...
Ver detalles
LNEYA Enfriadoras industriales Fabricante Proveedor