What is a laboratory glycol chiller What should I pay attention to
The laboratory glycol chiller is a common
cooling equipment in the laboratory. It is generally used to achieve the
temperature requirement of the cold source. What are the benefits?
1. Why choose a laboratory glycol chiller:
The single-machine self-cascade
refrigeration technology adopted has fast refrigeration speed, low noise and
simple installation. There are many sizes and models of laboratory
low-temperature refrigeration cycle devices. Users can choose models according
to their own needs, and can also choose isolation and explosion-proof options.
2. Commonly used refrigerants in laboratory
glycol chillers:
Commonly used water, brine, chlorinated
solution, and ethylene glycol in laboratory cryogenic refrigeration cycle
devices, the performance, price, and heat capacity of each refrigerant are
different, so the choice can be selected according to the needs.
The freezing point of ethylene glycol is
relatively low, the use temperature is -50 degrees, the performance is
relatively temperature, the price is cheaper, but it is corrosive. The
chlorine-containing solution has a low freezing point, high volatility, and
corrosiveness. The applicable temperature range is -50 to -100°C. Water has
a large specific heat, low density, low price and easy availability. It is
suitable for occasions where the refrigeration temperature is above 0°C. The salt
water can lower the freezing point temperature and expand the cooling range. It
is suitable for medium and low temperature refrigeration systems.
3. Points for attention when using the
laboratory glycol chiller:
A. Before use, you need to check to see if
the location of the device is correct to avoid problems during use.
B. When using the laboratory glycol
chiller, follow the operating instructions for operation, including turning on
and off the machine.
C. Pay attention to good maintenance work,
and perform regular maintenance regularly.
D. When the laboratory glycol chiller fails
during use, it should be solved in time. Some common failures have information
in the instruction manual, which can’t be solved. Contact the manufacturer to
solve it.
Resuma
Laboratory glycol chillers are used in many
industries such as chemicals, new energy, components, industries, etc., and you
need to pay attention to the quality of choice when choosing. Global consulting
sales@lneya.com.
Recomendaciones relacionadas
-
Refrigeración Cerrada Calefacción Circulador Manual de Mantenimiento Diario
2200Las circuladoras cerradas de refrigeración y calefacción de diferentes fabricantes tienen una determinada vida útil. Un funcionamiento y un mantenimiento razonables y correctos de los termostatos cerrados de refrigeración y calefacción pueden prolongar eficazmente su vida útil.
Ver detalles -
Introducción al uso de refrigeradores de precisión a prueba de explosiones
1759Wuxi Lneya solves the problem of how to charge refrigerants in the absence of refrigeration. 1. Connect all kinds of equipment well, close the three valve when the vacuum pressure is down to 133.3Pa, remove the hose from the suction port of the va...
Ver detalles -
-80 °C refrigerator manufacturer operating equipment points
1578When the user chooses the -80 °C refrigerator, it is definitely necessary to have a reliable quality. Wuxi Guanya (LNEYA)-80 °C refrigerator should pay attention to its operation details during operation to avoid equipment failure caused by improp...
Ver detalles -
Details of the types&functions and characteristics of industrial chillers
1537When it comes to industrial chillers, everyone must know it, but what are the specific types? It is a kind of cooling equipment that can continuously perform the cooling function, which is also an important manifestation of the function of industr...
Ver detalles
LNEYA Enfriadoras industriales Fabricante Proveedor