Why is There Frost Phenomenon in the Low Temperature Chiller Circulator?
Many refrigerador de baja temperatura circulators will frost when they are used, but there is no frost phenomenon in refrigerador de baja temperatura circulators. So, what’s the matter? Is it related to refrigeration?
First of all, why does the refrigerador de baja temperatura circulator frost? To find out why there is no frost in the refrigerador de baja temperatura circulator, it’s better to see why the the refrigerador de baja temperatura circulator frosts first. Frost is a white crystalline substance of water vapor. When water vapor suddenly encounters a very low temperature object, it will condense frost on its surface.
When the air in the the refrigerador de baja temperatura circulator meets the inner wall of the the refrigerador de baja temperatura circulator with lower temperature, it will form frost on its surface. This is the basic reason for the frost in the the refrigerador de baja temperatura circulator. The frosting of the the refrigerador de baja temperatura circulator will affect the efficiency of heat exchange, resulting in the decrease of refrigeration capacity, which requires manual removal by users.
Knowing why the cold water cooler circulator frosts, then why not the wind-cooled frost? Is it the opposite? The principle of air-cooled ultra-refrigerador de baja temperatura circulator is to use air to refrigerate. High temperature air flows through the built-in evaporator. Because of the high air temperature and the low evaporator temperature, the air temperature will be reduced by the direct heat exchange between the two.
At the same time, the cold air is blown into the ultra-low temperature water cooler circulator. The air-cooled ultra-low temperature water cooler circulator reduces the temperature of the ultra-low temperature water cooler circulator through this continuous circulation mode. However, there is always water vapor in the air. When water vapor is cooled, it will condense. So as long as there is heat exchange in the cryogenic water cooler circulator, frost will form. So where did the frost go?
In fact, the air-cooled ultra-low temperature water cooler circulator is not frost-free, but frost condensed on the evaporator. Because it is inside the cryogenic water cooler circulator, we can’t see it directly when we open the door of the cryogenic water cooler circulator, so it is called frost-free.
Recomendaciones relacionadas
-
Chip test dedicated TES-5 series preparation instructions
939The TES-5 series for chip testing is used for electronic component testing. How to accurately detect the chip is very important. So, how much do you know about the test preparation for the TES-5 series for chip testing? Before starting the TES-5 s...
Ver detalles -
Ultra-low temperature refrigeration circulator condenser maintenance instructions
1390Maintenance is an important task for users of ultra-low temperature refrigeration circulators. Wuxi Guanya LNEYA reminds that the maintenance of the condenser is a relatively important task in its maintenance work. So what should be paid attention...
Ver detalles -
LNEYA hot and cold machine SUNDI manual
1417The temperature range of the hot and cold machine ranges from -120 ° C to 350 ° C. It has superior performance and unique performance. It has high precision and intelligent temperature control. The high cooling power is from 0.5 to 1200 kW. High p...
Ver detalles -
How to Debug the Expansion Valve of Low Temperature Freezer?
1102The effective operation of low temperature freezer is relevant to the needed refrigerating effect. It is crucial to correct expansion valve if better cooling effect is wanted. So, how to debug the expansion valve of low temperature freezer?During ...
Ver detalles