Servicio global
30,000 +customers.
20+ countries.

Patentes de certificación
CE ,SGS, ISO certification.

Servicio posventa
24/7 solutions.

Equipo profesional
15+ years experience.

Control de calidad
Quality test.
Buscar en toda la estación
Diseñado y desarrollado especialmente para reactores de microcanales con pequeña capacidad de líquido, alta capacidad de intercambio térmico y gran caída de presión en el sistema de circulación. La tecnología de enfriamiento continuo a alta temperatura le proporciona un entorno de temperatura constante estable.
más bajo
Más alto
Precisión del control de temperatura
Medio y material
Modelo | WTD-255-2T Double Temp range WTD-255W-2T Double Temp range |
WTD-455-2T Double Temp range WTD-455W-2T Double Temp range |
|||
Rango de temperatura | -25°C~200°C | -45°C~250°C | |||
Temp resolution | 0.1K | ||||
Control panel | 7 inch colorful touch screen | ||||
Curva de datos | Data Curve Record | ||||
Date output | U disco formato excel | ||||
Control model | PID Adaptive controller | ||||
Potencia calorífica | 5,5 kW | 5,5 kW | 5,5 kW | 5,5 kW | |
Cooling capacity kW | 250°C | 5,5 kW | 5,5 kW | ||
200°C | 5,5 kW | 5,5 kW | 5,5 kW | 5,5 kW | |
100°C | 5kW | 5kW | 5 kW | 5kW | |
20°C | 5kW | 5kW | 5 kW | 5kW | |
-15°C | 2 kW | 2 kW | 4 kW | 4kW | |
-35°C | 1,5 kW | 1,5 kW | |||
Bomba de circulación máx. | 25L/min 3bar Double Line | 25L/min 3bar Double Line | |||
Cooling way | Air cooled + Water cooled | Air cooled + Water cooled | |||
Refrigerante | R404A | R404A | |||
Metal insulated hose | 1.8M*4 | 1.8M*4 | |||
Dimensión cm | 70*100*175 | 70*100*175 | |||
Potencia 380V 50HZ | 19kW MAX | 20kW MAX |
Reduce refrigerant consumption
WTD reactor temperature control system adopts fully enclosed pipeline design, and the internal flow channel is compact. Under the premise of ensuring the cooling effect, it can reduce the amount of refrigerant charged and reduce operation and maintenance costs.
Método de refrigeración
WTD reactor temperature control system provides two cooling methods: air cooling and water cooling. The evaporator used is a plate heat exchanger with higher heat exchange efficiency.
The WTD reactor temperature control system can keep the temperature in the reactor within the ideal range. Therefore, it is an important auxiliary equipment for microchannel reactors. At present, the WTD reactor temperature control system has been widely used in the fields of medicine, chemical industry etc.
30,000 +customers.
20+ countries.
CE ,SGS, ISO certification.
24/7 solutions.
15+ years experience.
Quality test.
Contactar con LNEYA