Normal & Low Temperature Chillers -40℃~160℃
Control Temperature & Flow Systems
For Vehicle Components Testing,Hydrogen energy industry
Control temperature & flow system supports one to many, meaning that one refrigeration and heating temperature control flow host can control 2-6 different test benches or demand temperature control flow devices. Support two one to many modes, one is that temperature/flow/pressure can be independently controlled (T-series), and the other is that temperature is consistent across multiple groups, and flow/pressure is independently controlled (S-series).(LNEYA’s chiller supports both indoor and outdoor options.)
The automotive industry must ensure that its products operate over this wide temperature range and do not fail or material fatigue under rapid temperature changes.
Therefore, material and component testing, including temperature simulation, is very important and indispensable for the automotive industry, including all suppliers.
On the test benches in the automotive industry, highly dynamic temperature control systems are used for material and component testing, which can achieve precise regulation and rapid temperature changes. Only precise temperature management can provide reliable and repeatable results. The temperature control system provides a constant temperature or a complex temperature curve to the test bench directly or indirectly through a liquid medium. In addition to the temperature of the medium, temperature control systems also allow precise control of flow rates and operating pressures. Temperature control systems are used primarily in two ways: They simulate external ambient conditions in climate chambers or replace internal systems, such as the cooling circuit of an engine. The latter allows realistic conditions to be created on test benches, where test specimens are supplied with coolant according to operational requirements, such as in a vehicle.
We supply our customers in the automotive industry with high-performance devices. They not only dynamically cover the entire temperature range from -40°C to +160°C and the rapid temperature changes required on test benches.
KRY series advantages
Resultados de estabilidad y repetibilidad de la producción eficientes;
Utilización de intercambiadores de calor de placas y calentadores de tuberías para mejorar los índices de refrigeración y calefacción;
Rango de temperatura muy amplio, sin necesidad de sustituir el medio líquido;
Sistema totalmente cerrado que prolonga la vida útil de los líquidos conductores térmicos;
Al adoptar una bomba de accionamiento magnético, no hay problemas de fugas en el sello del eje
LOW TEMPERATURE SERIES
KRY -20℃~+100℃
Modelo |
KRY-255 KRY-255W |
KRY-275 KRY-275W |
KRY-2A10 KRY-2A10W |
KRY-2A15 KRY-2A15W |
KRY-2A25 KRY-2A25W |
KRY-2A38W |
Rango de temperatura |
-20℃~+100℃ |
Precisión del control de temperatura |
±0.3℃ |
±0.3℃ |
±0.3℃ |
±0.3℃ |
±0.3℃ |
±0.3℃ |
Información sobre la temperatura |
Pt100 |
Pt100 |
Pt100 |
Pt100 |
Pt100 |
Pt100 |
Visualización de la temperatura |
0.01k |
0.01k |
0.01k |
0.01k |
0.01k |
0.01k |
Salida de caudal |
1~15 L/min |
1~25 L/min |
1~30 L/min |
1~40 L/min |
1~40 L/min |
1~40 L/min |
Precisión del caudal |
±0,2 L/min |
±0,2 L/min |
±0,2 L/min |
±0,2 L/min |
±0,2 L/min |
±0,2 L/min |
Potencia calorífica |
5,5 kW |
7,5 kW |
10kW |
15 kW |
25 kW |
38 kW |
Capacidad de refrigeración |
100℃ |
5,5 kW |
7,5 kW |
10kW |
15 kW |
25 kW |
38 kW |
20℃ |
5,5 kW |
7,5 kW |
10kW |
15 kW |
25 kW |
38 kW |
0℃ |
5,5 kW |
7,5 kW |
10kW |
15 kW |
25 kW |
38 kW |
-15℃ |
2,8 kW |
3,8 kW |
4,6 kW |
7kW |
12kW |
16 kW |
Tamaño de la conexión |
G3/4 |
G3/4 |
G3/4 |
G3/4 |
G3/4 |
G3/4 |
Refrigerado por agua tipo W a 25℃ |
1900L/H ZG3/4 |
2500L/H ZG3/4 |
3000L/H ZG1 |
4000L/H ZG1 |
6000L/H DN32 |
9000L/H DN40 |
Potencia 380V50HZ |
11 kW |
14 kW |
19 kW |
23 kW |
31 kW |
45 kW |
Dimensión cm |
55*100*175 |
55*100*175 |
70*100*175 |
80*120*185 |
100*150*185 |
100*150*185 |
Peso |
230 kg |
250 kg |
300 kg |
320 kg |
570 kg |
830 kg |
Opcional |
Extender a -40~+135℃ |
KRY -40℃~+100℃
Modelo |
KRY-455 KRY-455W |
KRY-475 KRY-475W |
KRY-4A10 KRY-4A10W |
KRY-4A15 KRY-4A15W |
KRY-4A25 KRY-4A25W |
KRY-4A38W |
KRY-4A60W |
Rango de temperatura |
-40℃~+100℃ |
-40℃~+100℃ |
-40℃~+100℃ |
-40℃~+100℃ |
-40℃~+100℃ |
-40℃~+100℃ |
-40℃~+100℃ |
Precisión del control de temperatura |
±0.3℃ |
±0.3℃ |
±0.3℃ |
±0.3℃ |
±0.3℃ |
±0.3℃ |
±0.3℃ |
Información sobre la temperatura |
Pt100 |
Pt100 |
Pt100 |
Pt100 |
Pt100 |
Pt100 |
Pt100 |
Visualización de la temperatura |
0.01k |
0.01k |
0.01k |
0.01k |
0.01k |
0.01k |
0.01k |
Salida de caudal |
1~25 L/min |
1~25 L/min |
1~25 L/min |
1~40 L/min |
1~40 L/min |
1~40 L/min |
1~40 L/min |
Precisión del caudal |
±0,2 L/min |
±0,2 L/min |
±0,2 L/min |
±0,2 L/min |
±0,2 L/min |
±0,2 L/min |
±0,2 L/min |
Potencia calorífica |
5,5 kW |
7,5 kW |
10kW |
15 kW |
25 kW |
38 kW |
60 kW |
Capacidad de refrigeración |
100℃ |
5,5 kW |
7,5 kW |
10kW |
15 kW |
25 kW |
38 kW |
60 kW |
20℃ |
5,5 kW |
7,5 kW |
10kW |
15 kW |
25 kW |
38 kW |
60 kW |
0℃ |
5,5 kW |
7,5 kW |
10kW |
15 kW |
25 kW |
38 kW |
60 kW |
-20℃ |
2,8 kW |
4,5 kW |
6kW |
10kW |
16 kW |
25 kW |
35 kW |
-35℃ |
1,2 kW |
1,8 kW |
2,5 kW |
4kW |
6,5 kW |
10kW |
15 kW |
Tamaño de la conexión |
ZG3/4 |
ZG3/4 |
ZG3/4 |
ZG3/4 |
ZG3/4 |
ZG3/4 |
ZG3/4 |
Tipo refrigerado por agua Wat25度 |
1900L/H ZG3/4 |
2500L/H ZG3/4 |
3000L/H ZG1 |
4000L/H ZG1 |
6000L/H DN32 |
9000L/H DN40 |
15000L/H DN50 |
Potencia 380V50HZ |
10kW |
14 kW |
17 kW |
25 kW |
38 kW |
58 kW |
84 kW |
Dimensión cm |
55*100*175 |
55*100*175 |
70*100*175 |
80*120*185 |
100*150*185 |
100*150*185 |
200*145*205 |
Peso |
250 kg |
280 kg |
320 kg |
360 kg |
620 kg |
890 kg |
1300KG |
Opcional |
Extender a -40~+135℃ |
KRY -40℃~+100℃ 2T
Modelo |
KRY-475/2T KRY-475W/2T |
KRY-4A15W/2T |
KRY-4A25W/2T |
KRY-4A38W/2T |
KRY-4A60W/2T |
Rango de temperatura |
-40℃~+100℃ |
Precisión del control de temperatura |
±0.3℃ |
±0.3℃ |
±0.3℃ |
±0.3℃ |
±0.3℃ |
Información sobre la temperatura |
Pt100 |
Pt100 |
Pt100 |
Pt100 |
Pt100 |
Visualización de la temperatura |
0.01k |
0.01k |
0.01k |
0.01k |
0.01k |
Precisión del control de caudal/Grupo |
1~25 L/min |
1~40 L/min |
1~40 L/min |
1~40 L/min |
1~40 L/min |
Flow rate accuracy/group |
±0,2 L/min |
±0,2 L/min |
±0,2 L/min |
±0,2 L/min |
±0,2 L/min |
Number of fuid output groups |
2 groups |
2 groups |
2 groups |
2 groups |
2 groups |
Pressure control/group |
0.2bar~2.5bar |
0.2bar~2.5bar |
0.2bar~2.5bar |
0.2bar~2.5bar |
0.2bar~2.5bar |
Potencia calorífica |
7.5kW*2 |
10kW*2 |
15kW*2 |
25kW*2 |
38kW*2 |
Capacidad de refrigeración |
100℃ |
7.5kW*2 |
15kW*2 |
25kW*2 |
38kW*2 |
60kW*2 |
20℃ |
7.5kW*2 |
15kW*2 |
25kW*2 |
38kW*2 |
60kW*2 |
0℃ |
7.5kW*2 |
15kW*2 |
25kW*2 |
38kW*2 |
60kW*2 |
-20℃ |
4.5kW*2 |
8.5kW*2 |
14kW*2 |
22kW*2 |
35kW*2 |
-35℃ |
1.8kW*2 |
4kW*2 |
6.5kW*2 |
10kW*2 |
15kW*2 |
Water-cooled type Wat 20度 |
4000L/H ZG1 |
8000L/H DN32 |
12000L/H DN40 |
20000L/H DN50 |
30000L/H DN65 |
Dimensión cm |
28 kW |
45 kW |
70kW |
108kW |
158kW |
Water-cooled cm |
80*100*185 |
100*150*185 |
200*145*205 |
200*145*205 |
250*145*225 |
Peso |
660KG |
850KG |
1350KG |
1800KG |
2600KG |
Opcional |
Extender a -40~+135℃ |
KRY -20℃~+100℃ 6S
Modelo |
KRY-2A25W/6S |
KRY-2A38W/6S |
KRY-2A60W/6S |
Rango de temperatura |
-20℃~+100℃ |
Precisión del control de temperatura |
±0.3℃ |
±0.3℃ |
±0.3℃ |
Información sobre la temperatura |
Pt100 |
Pt100 |
Pt100 |
Visualización de la temperatura |
0.01k |
0.01k |
0.01k |
Precisión del control de caudal/Grupo |
1~25 L/min |
1~25 L/min |
1~40 L/min |
Flow rate accuracy/group |
±0,2 L/min |
±0,2 L/min |
±0,2 L/min |
Number of fuid output groups |
6 grupos |
6 grupos |
6 grupos |
Pressure control/group |
0.2bar~2.5bar |
0.2bar~2.5bar |
0.2bar~2.5bar |
Potencia calorífica |
15 kW |
25 kW |
38 kW |
Capacidad de refrigeración |
100℃ |
25 kW |
38 kW |
60 kW |
20℃ |
25 kW |
38 kW |
60 kW |
0℃ |
25 kW |
38 kW |
60 kW |
-15℃ |
10kW |
15 kW |
24 kW |
Water-cooled type Wat 20度 |
8000L/H DN40 |
12000L/H DN50 |
20000L/H DN65 |
Potencia 380V50HZ |
36 kW |
51kW |
75 kW |
Water-cooled cm |
200*145*205 |
200*145*205 |
200*145*205 |
Peso |
900 kg |
1100kg |
1750kg |
KRY -40℃~+100℃ 6S
Modelo |
KRY-4A25W/6S |
KRY-4A38W/6S |
KRY-4A60W/6S |
Rango de temperatura |
-40℃~+100℃ |
Precisión del control de temperatura |
±0.3℃ |
±0.3℃ |
±0.3℃ |
Información sobre la temperatura |
Pt100 |
Pt100 |
Pt100 |
Visualización de la temperatura |
0.01k |
0.01k |
0.01k |
Precisión del control de caudal/Grupo |
1~25 L/min |
1~25 L/min |
1~40 L/min |
Flow rate accuracy/group |
±0,2 L/min |
±0,2 L/min |
±0,2 L/min |
Number of fuid output groups |
6 grupos |
6 grupos |
6 grupos |
Pressure control/group |
0.2bar~2.5bar |
0.2bar~2.5bar |
0.2bar~2.5bar |
Potencia calorífica |
15 kW |
25 kW |
38 kW |
Capacidad de refrigeración |
100℃ |
25 kW |
38 kW |
60 kW |
20℃ |
25 kW |
38 kW |
60 kW |
0℃ |
25 kW |
38 kW |
60 kW |
-20℃ |
14 kW |
22kW |
35 kW |
-35℃ |
5kW |
8kW |
13kW |
Water-cooled type Wat 20度 |
8000L/H DN40 |
12000L/H DN50 |
18000L/H DN65 |
Potencia 380V50HZ |
38 kW |
55 kW |
82 kW |
Dimensión cm |
200*145*205 |
200*145*205 |
200*145*205 |
Peso |
900 kg |
1200kg |
1950kg |
Opcional |
Extender a -40~+135℃ |
NORMAL TEMPERATURE SERIES
KRY 0℃~+100℃
Modelo |
KRY-25 |
KRY-55 |
KRY-75 |
KRY-A10 |
KRY-A15 KRY-A15W |
KRY-A25 KRY-A25W |
KRY-A38W |
KRY-A60W |
Rango de temperatura |
0℃~+100℃ |
Precisión del control de temperatura |
±0.3℃ |
±0.3℃ |
±0.3℃ |
±0.3℃ |
±0.3℃ |
±0.3℃ |
±0.3℃ |
±0.3℃ |
Información sobre la temperatura |
Pt100 |
Pt100 |
Pt100 |
Pt100 |
Pt100 |
Pt100 |
Pt100 |
Pt100 |
Visualización de la temperatura |
0.01k |
0.01k |
0.01k |
0.01k |
0.01k |
0.01k |
0.01k |
0.01k |
Salida de caudal |
2~20 L/min |
2~25 L/min |
2~25 L/min |
2~25 L/min |
2~25 L/min |
2~25 L/min |
5~50 L/min |
5~50 L/min |
Precisión del caudal |
±0,2 L/min |
Potencia calorífica |
2,5 kW |
5,5 kW |
7,5 kW |
10kW |
15 kW |
15 kW |
25 kW |
38 kW |
Capacidad de refrigeración |
100℃ |
2,5 kW |
5,5 kW |
7,5 kW |
10kW |
15 kW |
25 kW |
38 kW |
60 kW |
20℃ |
2,5 kW |
5,5 kW |
7,5 kW |
10kW |
15 kW |
25 kW |
38 kW |
60 kW |
5℃ |
1,8 kW |
3,8 kW |
5,2 kW |
7kW |
11 kW |
18 kW |
27 kW |
42kW |
Tamaño de la conexión |
G3/4 |
G3/4 |
G3/4 |
G3/4 |
G3/4 |
G3/4 |
G3/4 |
G3/4 |
Tipo refrigerado por agua Wat25度 |
|
|
|
|
3200L/H ZG1 |
6000L/H G1 1/4 |
9000L/H DN40 |
15000L/H DN50 |
Potencia 380V50HZ |
4,5kW220V |
8,5 kW |
11,5 kW |
16 kW |
18 kW |
28 kW |
40 kW |
61 kW |
Dimensión cm |
50*85*145 |
55*100*175 |
55*100*175 |
70*100*175 |
80*120*185 |
100*150*185 |
100*150*185 |
100*150*185 |
Peso |
220 kg |
250 kg |
280 kg |
320 kg |
360 kg |
620 kg |
890 kg |
1300KG |
KRY 0℃~+100℃ 2T
Modelo |
KRY-25/2T |
KRY-55/2T |
KRY-75/2T |
KRY-A10/2T |
KRY-A15W//2T |
KRY-A25W/2T |
KRY-A38W/2T |
KRY-A60W/2T |
Rango de temperatura |
0℃~+100℃ |
Precisión del control de temperatura |
±0.3℃ |
±0.3℃ |
±0.3℃ |
±0.3℃ |
±0.3℃ |
±0.3℃ |
±0.3℃ |
±0.3℃ |
Información sobre la temperatura |
Pt100 |
Pt100 |
Pt100 |
Pt100 |
Pt100 |
Pt100 |
Pt100 |
Pt100 |
Visualización de la temperatura |
0.01k |
0.01k |
0.01k |
0.01k |
0.01k |
0.01k |
0.01k |
0.01k |
Salida de caudal |
2~20 L/min |
2~25 L/min |
2~25 L/min |
2~25 L/min |
2~25 L/min |
2~25 L/min |
5~50 L/min |
5~50 L/min |
Precisión del caudal |
±0,2 L/min |
Potencia calorífica |
2.5kW*2 |
5.5kW*2 |
7.5kW*2 |
10kW*2 |
15kW*2 |
15kW*2 |
25kW*2 |
38kW*2 |
Capacidad de refrigeración |
100℃ |
2.5kW*2 |
5.5kW*2 |
7.5kW*2 |
10kW*2 |
15kW*2 |
25kW*2 |
38kW*2 |
60kW*2 |
20℃ |
2.5kW*2 |
5.5kW*2 |
7.5kW*2 |
10kW*2 |
15kW*2 |
25kW*2 |
38kW*2 |
60kW*2 |
5℃ |
1.8kW*2 |
3.8kW*2 |
5.2kW*2 |
7kW*2 |
11kW*2 |
18kW*2 |
27kW*2 |
42kW*2 |
Tamaño de la conexión |
ZG3/4 |
ZG3/4 |
ZG3/4 |
ZG3/4 |
ZG3/4 |
ZG3/4 |
ZG3/4 |
ZG3/4 |
Tipo refrigerado por agua Wat25度 |
|
|
|
|
5600L/H DN32 |
10000L/H DN40 |
17000L/H DN50 |
24000L/H DN65 |
Potencia 380V50HZ |
9kW |
19 kW |
23 kW |
29kW |
34 kW |
52kW |
80kW |
120 kW |
Dimensión cm |
55*100*175 |
70*100*175 |
80*120*185 |
100*150*185 |
100*150*185 |
200*145*205 |
200*145*205 |
250*145*225 |
Peso |
260KG |
320KG |
400KG |
580KG |
750KG |
1250KG |
1600KG |
2400KG |
KRY 0℃~+100℃ 6S
Modelo |
KRY-A25W/6S |
KRY-A38W/6S |
KRY-A60W/6S |
Rango de temperatura |
0℃~+100℃ |
Precisión del control de temperatura |
±0.3℃ |
±0.3℃ |
±0.3℃ |
Información sobre la temperatura |
Pt100 |
Pt100 |
Pt100 |
Visualización de la temperatura |
0.01k |
0.01k |
0.01k |
Precisión del control de caudal/Grupo |
2~25 L/min |
2~25 L/min |
2~25 L/min |
Flow rate accuracy/group |
±0.2L/min |
Number of fuid output groups |
6 grupos |
6 grupos |
6 grupos |
Pressure control/group |
0.2bar~2.5bar |
0.2bar~2.5bar |
0.2bar~2.5bar |
Potencia calorífica |
15 kW |
25 kW |
38 kW |
Capacidad de refrigeración |
100℃ |
25 kW |
38 kW |
60 kW |
20℃ |
25 kW |
38 kW |
60 kW |
5℃ |
18 kW |
27 kW |
42kW |
Water-cooled type Wat 20度 |
6000L/H DN32 |
9000L/H DN40 |
15000L/H DN50 |
Potencia 380V50HZ |
38 kW |
55 kW |
82 kW |
Dimensión cm |
200*145*205 |
200*145*205 |
200*145*205 |
Peso |
900 kg |
1200kg |
1950kg |
Frequency Conversion Series
KRYZ -40℃~+100℃
Modelo |
KRYZ-475 KRYZ-475W |
KRYZ-4A15W |
KRYZ-4A25W |
Rango de temperatura |
-40℃~+100℃ |
-40℃~+100℃ |
-40℃~+100℃ |
Precisión del control de temperatura |
±0.1℃ |
±0.1℃ |
±0.1℃ |
Información sobre la temperatura |
Pt100 |
Pt100 |
Pt100 |
Visualización de la temperatura |
0.01k |
0.01k |
0.01k |
Salida de caudal |
1~25 L/min |
1~25 L/min |
1~25 L/min |
Precisión del caudal |
±0.1 L/min |
±0.1 L/min |
±0.1 L/min |
Potencia calorífica |
7,5 kW |
15 kW |
25 kW |
Refrigeración capacidad |
100℃ |
7,5 kW |
15 kW |
25 kW |
20℃ |
7,5 kW |
15 kW |
25 kW |
0℃ |
7,5 kW |
15 kW |
25 kW |
-20℃ |
4,5 kW |
10kW |
16 kW |
-35℃ |
1,8 kW |
4kW |
6,5 kW |
Tamaño de la conexión |
G3/4 |
G3/4 |
G3/4 |
Water-cooled At20℃ |
2500L/H ZG3/4 |
4000L/H ZG1 |
6000L/H DN32 |
Potencia 380V50HZ |
14 kW |
25 kW |
38 kW |
Dimensión cm |
55*85*175 |
70*100*175 |
80*120*185 |
Peso |
280 kg |
360 kg |
620 kg |
Opcional |
Extended to -40 ℃~+135 ℃ |
KRYZ -40℃~+100℃ 2T
Modelo |
KRYZ-475W/2T |
KRYZ-4A15W/2T |
KRYZ-4A25W/2T |
Rango de temperatura |
-40℃~+100℃ |
Precisión del control de temperatura |
±0.1℃ |
±0.1℃ |
±0.1℃ |
Información sobre la temperatura |
Pt100 |
Pt100 |
Pt100 |
Visualización de la temperatura |
0.01k |
0.01k |
0.01k |
Salida de caudal |
1~25 L/min |
1~25 L/min |
1~25 L/min |
Precisión del control de caudal/Grupo |
±0.1 L/min |
±0.1 L/min |
±0.1 L/min |
Number of fuid output groups |
2 groups |
2 groups |
2 groups |
Pressure control/group |
0.2bar~2.5bar |
0.2bar~2.5bar |
0.2bar~2.5bar |
Potencia calorífica |
7.5kW*2 |
10kW*2 |
15kW*2 |
Refrigeración capacidad |
100℃ |
7.5kW*2 |
15kW*2 |
25kW*2 |
20℃ |
7.5kW*2 |
15kW*2 |
25kW*2 |
0℃ |
7.5kW*2 |
15kW*2 |
25kW*2 |
-20℃ |
4.5kW*2 |
8.5kW*2 |
14kW*2 |
-35℃ |
1.8kW*2 |
4kW*2 |
6.5kW*2 |
Water-cooled At20℃ |
4000L/H ZG1 |
8000L/H DN32 |
12000L/H DN40 |
Dimensión cm |
80*120*185 |
100*150*185 |
200*145*205 |
Potencia 380V50HZ |
28 kW |
45 kW |
70kW |
Peso |
660KG |
850 kg |
1350kg |
Opcional |
Extended to -40 ℃~+135 ℃ |
Hourly power consumption kWh |
-40℃ |
-10℃ |
20℃ |
KRY-475 |
5 |
6.2 |
8.4 |
KRYZ-475 |
2.2 |
4 |
4.8 |
Frequency conversion saves power consumption |
56% |
35% |
43% |
Explain |
1. Empty load test data; 2. The test condition is an ambient temperature of 20 ℃; 3. Flow rate 15L/min |
Oil cooling chiller for motor test
KRYZ 0℃~+160℃
Modelo |
KRYO-A15W |
KRYO-A25W |
KRYO-A38W |
KRYO-A15W2S |
KRYO-A25W2S |
KRYO-A38W2S |
Rango de temperatura |
0℃ ~ +160℃ Different viscosity oils have different temperature ranges |
Precisión del control de temperatura |
±0.3℃ |
Precisión del caudal |
±0.2L/min |
Control de la presión |
0.2bar~2.5bar |
Potencia calorífica |
15 kW |
25 kW |
38 kW |
15 kW |
25 kW |
38 kW |
Refrigeración capacidad |
125℃ |
15 kW |
25 kW |
38 kW |
15 kW |
25 kW |
38 kW |
20℃ |
12kW |
20 kW |
30 kW |
12kW |
20 kW |
30 kW |
Refrigerante |
R410A |
Refrigerante secundario |
Oil |
Tamaño de la conexión |
G3/4 |
Water-cooled At20℃ |
3000L/H |
4200L/H |
6200L/H |
3000L/H |
4200L/H |
6200L/H |
Tamaño de la conexión |
G3/4 |
G3/4 |
G1 |
G3/4 |
G3/4 |
G1 |
direct cooling heating series
Can meet the direct cooling/direct heating for battery pack and vehicle testing and testing. This equipment is mainly used for cooling and heating capacity testing. It uses variable frequency compressor with adjustable output;
KRYZ 0℃~+160℃
Modelo |
KRYZ-5W-ZLH |
KRYZ-5W-ZL |
KRYZ-5-ZLH |
KRYZ-5-ZL |
Capacidad de refrigeración |
0.5kW~10kW |
0.5kW~10kW |
Potencia calorífica |
0.5kW~10kW |
|
Undercooling degree |
Refrigeration 0k~8K Heating at 0k~6k in low-temp environment, 6k~20k |
Refrigeration 0k~8K |
Overheating degree |
Refrigeration 2k~20k Heating 2k~10k |
Refrigeration 2k~20k |
Condensation pressure control accuracy |
Better than ±50kpa |
Better than ±50kpa |
Suction pressure |
300kpa~600kpa ±10kpa |
300kpa~600kpa ±10kpa |
Battery pack testing environment Temp |
-40℃~50℃ |
-40℃~50℃ |
multi-channel independent temperature control
Adopts LNEYA PLC control, simple menu navigation, 7″ color large screen, multi-faceted and multi-functional images to display comprehensive important data information. The newly added safety measures ensure continuous unattended operation. All relevant operating status data are continuously monitored and visualized on the touch screen. Supports one-to-many multi-channel independent control, and each group can be set independently.
Appearance details
Application cases
La unidad de prueba necesita utilizar curvas específicas de cambio de temperatura y registrar los cambios de temperatura; El rango de temperatura suele ser de -40 ℃ a 100 ℃ (puede ampliarse a 150 ℃); Al realizar la prueba de tolerancia, suele hacerse en un ciclo infinito.
High adaptability and wide applicationS
Suitable for more simulation test temperature control
Equipment application: new energy battery pack, battery module, battery cell, motor and controller, charger, DC/DC converter, electronic pump
REQUEST A QUOTE
Recommended products
Temperature Control :-5℃~-150℃
Temperature control for Various reactors, distillation or extraction systems, laboratories, research institutes, chemical, pharmaceutical, petrochemical, biochemical, medical, hospital, research and development workshops, semiconductor testing, aerospace, biology.
Control de temperatura :-120℃~350℃
Temperature control for high pressure reactor;Double-layer glass reactor;Double-layer reactor;Microchannel Reactor;Distillation system;Material aging test;Vacuum chamber etc.
Control de temperatura: -40℃~100℃
Simulación de temperatura para pruebas de calidad de vehículos: prueba de duración de la batería, banco de pruebas de inyectores/motores de combustible, prueba de airbags, banco de pruebas de componentes, etc. Puede simular las condiciones ambientales externas en la cámara climática o sustituir el sistema interno, lo que puede crear las condiciones de temperatura reales necesarias para el banco de pruebas.
Control de temperatura: -85℃~250℃
Suitable for semiconductor process wet washing, photolithography, etching, chemical meteorological deposition, physical meteorological deposition, and the electronics industry (photolithography process)