Serie UST
APLICACIONES
Suitable for temperature control in more usage scenarios
Used with reactors, reactors, microchannels, distillation systems, etc., and also used for heating and cooling of other equipment. Widely used in pharmaceutical, chemical, biological, semiconductor, new materials and other industries
Características del producto
Parámetros del producto
Modelo | UST-5530 UST-5530W | UST-7530 UST-7530W | UST-A1030 UST-A1030W | UST-A1530 UST-A1530W | UST-A2530 UST-A2530W | UST-A3830 UST-A3830W | UST-A6030 UST-A6030W | UST-A9530 UST-A9530W | |
Rango de temperatura | RT+10℃~+300℃ | ||||||||
Sistema de control | Retroalimentación PID + Nuestro cálculo especial de control dinámico, controlador PLC | ||||||||
Modo de control | Process temp control and jacket temp control mode | ||||||||
Temp difference | Ajustar o controlar la diferencia de temperatura entre el aceite de la camisa y el proceso de la materia prima | ||||||||
Editor de programas | 5 programas, cada programa puede editar 40 pasos | ||||||||
Communication protoco | Protocolo MODBUS RTU, interfaz RS485 | ||||||||
Material temp feedback | PT100 OR 4~20mA or communication(normal: PT100) | ||||||||
Información sobre la temperatura | The temp of three points: the inlet and outlet of equipment, reactor material temperature(external temp sensor) | ||||||||
Medium temp acccuracy | ±0.5℃ | ±1℃ | |||||||
Precisión de la temperatura del material | ±1℃ | ||||||||
Potencia calorífica kW | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | 95 | |
Refrigeración capacidad |
300 ℃ | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | 95 |
200 ℃ | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | 95 | |
100 ℃ | 4 | 5 | 7 | 12 | 20 | 30 | 48 | 76 | |
65 ℃ | 1.8 | 2.2 | 3 | 5 | 8.5 | 12 | 19 | 30 | |
Bomba de circulación max L/min bar |
35 | 50 | 50 | 110 | 150 | 200 | 250 | 400 | |
2 | 2 | 2 | 2.5 | 2.5 | 2.5 | 2.5 | 2.5 | ||
Panel de control | 7-inch touch screen, show temp curve\EXCEL data output | ||||||||
Protección de seguridad | Self-diagnosis function; freezer overload protection; high pressure switch, overload relay, thermal protection device, high temperature protection and temp fault protection |
||||||||
Closed circulation sistema |
The whole system is full closed circulation, there is no oil mist at high temp and no water vapor at low temp, pressure do not rise up when system is running. The system will supply oil automatically at low temperature |
||||||||
Connection siz | ZG3/4 | ZG3/4 | ZG3/4 | ZG1 | DN32 PN10 | DN40 PN10 | DN40 PN10 | DN50 PN10 | |
Connection size(water port) | ZG3/4 | ZG3/4 | ZG3/4 | ZG1 | DN32 PN10 | DN40 PN10 | DN40 PN10 | DN50 PN10 | |
Dimensión cm | 40*70*130 | 45*70*160 | 40*70*160 | 70*100*175 | 70*100*175 | 80*120*185 | 150*100*185 | 200*145*205 | |
Peso en kg | 110 | 120 | 160 | 195 | 265 | 395 | 615 | 950 | |
Power MAX 380V 50HZ |
7kW | 9kW | 12kW | 17 kW | 28 kW | 41 kW | 65 kW | 96 kW | |
Shell materia | Cold rolled sheet (REL7035) |
Contacto
Envíenos su solicitud y nos pondremos en contacto con usted en 24 horas