Automotive antifreeze test test temperature control system

When it comes to car antifreeze, we all know that its main function is to prevent the coolant from freezing and cracking the radiator and freezing the engine cylinder block or cover when we stop in the cold winter. Make the cooling system in the best working condition and ensure the normal working temperature of the engine.
The freezing point of water is 0°C, and ordinary antifreeze can reach -40°C, while high-quality antifreeze should be able to reach about -60°C, and the antifreeze has a high boiling point. The boiling point of water is 100 °C, and the boiling point of high-quality antifreeze coolant is usually 110 °C above zero, so it is more difficult to boil antifreeze coolant than water in summer.
Antifreeze detection items: freezing point detection, antifreeze detection, low temperature stability, thermal stability, etc. In these tests, temperature control is left off. When the testing organization carries out these testing items, it is necessary to ensure the constant temperature environment, cooling and heating temperature difference, time and so on during the testing process.
LNEYA automotive antifreeze cooling, heating, temperature control and flow system KRY series equipment is the temperature and flow control equipment required by this type of organization. The temperature range is minus 40 degrees to 100 degrees. The temperature changes during the test are visualized, and the data storage and report analysis can be exported for the convenience of the technicians of the testing organization.
The temperature test mentioned here is the high temperature endurance test and the low temperature endurance test. The low temperature endurance test mainly tests the cold start performance, the charging and discharging ability, the charging and discharging ability of the battery pack at high temperature, the cooling function of the battery pack and the overheat protection strategy.
Our LNEYA KRY series cooling, heating, temperature and flow control systems are the best choice for testing institutions, saving costs and increasing the efficiency and accuracy of testing.
Recomendaciones relacionadas
-
The Phenomenon of Ice Jam in Low Temperature Chiller System
832The phenomenon of ice jam in low temperature chiller system is mainly due to the excessive water in the refrigeration system. With the continuous circulation of refrigerants, the water in the refrigeration system gradually concentrates at the outl...
Ver detalles -
Main differences between indoor chillers and outdoor chillers
856Although indoor chillers and outdoor chillers are both devices used to provide cold water to meet specific cooling needs, they have significant differences in design, installation location, working environment, and heat dissipation methods...
Ver detalles -
El sistema de refrigeración del motor comprueba el efecto de la temperatura de condensación
1265El sistema de refrigeración del motor prueba el condensador. En condiciones normales, la primera mitad de la tubería de calor está muy caliente, y su temperatura tiene un lento y lento descenso gradual en el balance de potencia. La sensibilidad térmica de la segunda mitad del hea...
Ver detalles -
Noise description of common faults in high and low temperature integrated equipment
1197High-low temperature integrated machine equipment may cause malfunction due to improper operation, then how to deal with noise failure of the equipment, and then analyze the noise too high. The suction of high and low temperature integrated equipm...
Ver detalles