Cómo prolongar la vida útil del sistema de refrigeración por glicol?
In order to extend the service life of your glycol chiller in industrial applications, please pay attention to the following points·

1. Use automobile grade antifreeze carefully
Do not use automobile grade or unqualified antifreeze. Because this glycol is not manufactured for industrial applications, it may cause a variety of problems and shorten the service life of your glycol chiller system.
2. Comply with local regulations.
Experts have designed different rules and regulations according to the environmental requirements of this specific area. These are called local regulations, which not only provide safe operation, but also prolong the service life of ethylene glycol chiller system for your industrial application.
3. Fluid filtration and equipment maintenance.
Another secret to prolong the service life of ethylene glycol chiller system is to use fluid filter and carry out fluid maintenance. Operate the equipment as specified in the manufacturer’s manual.
4. Perform all preventive and corrective maintenance.
All planned and unplanned maintenance must be performed to extend the service life of the glycol chiller system· Provide regular maintenance list for all users, such as cleaning, lubrication, dust removal and filter replacement. All inspections are completed in time according to the instructions in the manufacturer’s manual.
5. On time calibration of equipment.
Stickers are attached to all equipment requiring calibration. This shows the calibration date, all of which should be calibrated in time to improve the efficiency of the measuring instrument and prolong the service life of your glycol cooling system.
Recomendaciones relacionadas
-
Solución a la imposibilidad de enfriar el enfriador industrial de recirculación de alta y baja temperatura
1155Cuando se utiliza el sistema de refrigeración por recirculación de alta y baja temperatura, ¿cuál es la causa general de que no se pueda reducir la alta temperatura? En primer lugar, analicemos el principio y el método de refrigeración. El sistema...
Ver detalles -
Classification and advantages and disadvantages of water-cooled chillers
1343Industrial chillers are divided into air-cooled industrial chillers and water-cooled industrial chillers. Today we will discuss the classification, advantages and disadvantages of water-cooled chillers. Advantages of water-cooled chillers: 1. Inte...
Ver detalles -
The use and characteristics of the SUNDI series of high and low temperature cooling circulators
1228The SUNDI series of high and low temperature cooling circulators are equipment for direct or auxiliary heating in the fields of biology, physics, chemical engineering, medical treatment, environmental protection, etc. Moreover, the temperature con...
Ver detalles -
The Following Works Should Be Done Before Starting Industrial Chillers
9912. For the compressor unit with water system, carefully check whether the cooling water system and chilled water system have water, and whether the water pressure is normal, whether the pipeline system of cooling water and chilled water is unblock...
Ver detalles