The Advantages Of The Industrial Chiller For Cascade Cryogenic Refrigeration System
Cascade cryogenic refrigeration system is a low-temperature refrigeration system which uses more than two refrigerants and combines them with heat exchangers (condenser evaporators) in more than two systems. For binary cascade refrigeration system chiller, it consists of two separate refrigeration systems. One is the high temperature system, the other is the low temperature system. The cryogenic system is used to cool the environmental laboratory, while the high-temperature system is used to cool the exhaust gas of the cryogenic system and condensate it at a lower temperature. This also achieves the purpose of reducing compression ratio and improving gas transmission coefficient.
The advantages of the industrial chiller for cascade cryogenic refrigeration system are the use of medium-pressure refrigerants suitable for high-temperature systems and high-pressure refrigerants suitable for low-temperature systems. The specific capacity of high pressure refrigerant gas at low temperature is much smaller than that of medium pressure refrigerant. Therefore, the refrigeration capacity of the same type of compressor for cascade refrigeration is several times larger than that of two-stage compression refrigeration at low temperature. The use of cascade refrigeration system water cooler can save a lot of investment and building area. Moreover, the high-pressure refrigerant operates at a low temperature with an inhalation pressure greater than or close to one atmosphere, and it does not often infiltrate into the system like a two-stage cryogenic system.
The cascade refrigeration system can be used for industrial water chillers, except that the user’s requirement varies greatly and the ambient temperature is above – 55 C. At present, there are more and more cold sources using cascade refrigeration system as cryogenic experimental equipment.
Recomendaciones relacionadas
-
Description of driver chip power supply in chip test temperature control system
900The chip test temperature control system is mainly for the cold heat source test equipment for various drive chips. Before the operation of the Wuxi Guanya chip test temperature control system, the user needs to know the power of the drive chip. I...
Ver detalles -
High and low temperature alternating wet heat shock test box function description
908Consumers need to pay attention to the performance of the high and low temperature alternating wet heat shock test chamber. LNEYA's test chamber is closer to the needs of the purchasing company. The high and low temperature alternating heat and hu...
Ver detalles -
Start-up work for new energy thermal management
985In the pipeline selection of new energy thermal management, if the use of improper/damaged hoses and/or hose joints will result in injury, the new energy thermal management is limited by the temperature, caliber, installation method, etc. Tube, me...
Ver detalles -
Aceite de refrigeración para cajas de impacto en frío y caliente de material de ultra alta temperatura
1175The ultra-high temperature material impact test chamber test device has too much frozen oil in the evaporator, which can also cause insufficient cooling and cause slow cooling. The oil stored in the evaporator of the ultra-high temperature materia...
Ver detalles