LNEYA semiconductor refrigeration unit common fault description
If a high-voltage alarm occurs in the semiconductor refrigeration unit, it is necessary to check whether the external piping is blocked or dirty. Clean and remove in time. If it is an air-cooled semiconductor refrigeration device, it is necessary to check the space ventilation condition of the semiconductor refrigeration device. If the space is small and the ventilation is not good, it is easy to cause a high-pressure alarm. In addition, if the compressor discharge pressure is too high, pressure relief is required. Turn on the pressure relief valve and put some gas on it.
Leakage refrigerant is one of the more common faults in semiconductor refrigeration equipment. There are many causes of refrigerant leakage in refrigeration systems of semiconductor refrigeration equipment, mainly in the welding area, which has its own manufacturing problems and is caused by customers. Leaking the refrigerant directly causes the semiconductor refrigeration unit to be unable to cool, and it is necessary to check for leaks. Check that it is leaking refrigerant in that place, and then make it up.

The low-temperature alarm and leakage refrigerant of the semiconductor refrigeration device are closely related. The first thing to do is to check whether the refrigerant is leaking. Most of the low-voltage conditions are caused by the leakage of the refrigerant in the semiconductor refrigeration device. Therefore, it is necessary to check the refrigerant and still need to check for leaks. If the compressor of the semiconductor refrigeration unit does not work, it is necessary to check whether the water pump of the semiconductor refrigeration device is good or bad. If the water pump is good, it is necessary to see if the water in the semiconductor refrigeration device tank can be replenished, and then check the current.
Since the semiconductor industry has certain requirements for the operation efficiency of the semiconductor refrigeration device, it is better for the semiconductor refrigeration device to avoid these faults as much as possible.
Recomendaciones relacionadas
-
Necessity Of New Energy Electric Vehicle Battery Test System
888The battery performance of new energy vehicles directly determines the experience of new energy vehicle end users. The electric vehicle battery test system needs to test the performance reliability of new energy vehicle batteries. With the develop...
Ver detalles -
La razón por la que el termostato de refrigeración Chiller de repente no arranca
1024Si se produce alguna situación inesperada durante el uso del termostato de refrigeración Chiller, es importante identificar rápidamente las razones específicas antes de resolverlas, con el fin de abordar eficazmente diversas cuestiones. Por ejemplo, ¿cuál es el re...
Ver detalles -
How to replace the four-way valve of the chilled water machine?
1081The four-way valve of the chilled water machine needs to be replaced in time after a long period of use, so how to replace it? You can look at the suggestions. When replacing the chilled water machine, you need to remove the connecting pipe conne...
Ver detalles -
Precauciones para el uso del control de la temperatura de enfriamiento y calentamiento de la destilación molecular
1006El sistema de control de temperatura de refrigeración y calefacción LNEYA de la serie SUNDI se utiliza conjuntamente para controlar la temperatura en el proceso de destilación molecular. ¿Qué hay que tener en cuenta durante el uso? Si el método de destilación molecular ca...
Ver detalles