DR series -70℃
- Precisión del control de temperatura±0.1℃
- Potencia calorífica2KW~7.5KW
- Capacidad de refrigeración1KW~6KW
Application principle
Additional filtration of oil and particulate matter, the air flow passes through a pre-filter with a filtration grade of 0.01 μm to prevent the desiccant from being contaminated by dust and oil (oil will greatly shorten the service life of the desiccant).
The compressed air dryer consists of multiple groups of filter elements filled with desiccant. The aerosol compressed air flows alternately through multiple groups of filter elements, and the moisture in the air will accumulate on the surface of the dryer. After the filtration process reaches a predetermined duration, the air flow will switch to other filter elements, and a part of the air flow (purge air flow) will be used to regenerate the dryer of the first filter element. The purge air flow will be released into the atmosphere. The service life of the desiccant is about 15,000 working hours. “
Parámetros detallados
Modelo | DR-300 | DR-600 | DR-1200 |
Pressure range | 0.65~1.0Mpa | ||
Dew point temperature | -70℃ | ||
Processing gas volume | 425L/Min | 900L/Min | 1750L/Min |
Finished gas volume | 300L/Min | 600L/Min | 1200L/Min |
Tamaño de la interfaz | ZG1/2 | ZG1/2 | ZG3/4 |
Power supply power | 220V 15W | ||
Dimensions | 200*180*1250 | 450*180*1250 | 450*180*1250 |
SOLICITAR PRESUPUESTO
Productos recomendados
Mandril serie MD
-75℃ a 225°C Modelo MD-708 MD-712 MDL-708 Temp. Rango -75℃~225℃ -75℃~225℃ -75℃~225℃ Precisión de control de temperatura ±0.1℃ ±0.1℃ ±0.1℃ uniformidad de temperatura ±1℃ ±1℃ ±1℃ Planitud ±50um ±50um ±50um Tamaño de la tableta 200mm de diámetro d...
YQH 0℃~-75℃
Adecuado para la recuperación de diversos gases volátiles COVs; Enfriamiento rápido, alta eficiencia, cumpliendo con diferentes requisitos de temperatura de condensación, baja temperatura puede alcanzar -75 ° C Proviene principalmente de la limpieza, pegamento ...
FLT-100℃~90℃
Refrigerador de un canal refrigerado por aire, diseñado principalmente para máquinas de grabado. Se utiliza para proporcionar un control independiente de la temperatura de las paredes laterales de la cámara.
FLTZ -45℃~90℃
Método de calentamiento dentro de 40 ℃ adopta un compresor de calefacción de gas caliente diseño totalmente cerrado, y la máquina funciona continuamente durante 24 horas El dispositivo de control de temperatura del semiconductor Chiller se utiliza principalmente para p...